Shear stress increases hydraulic conductivity of cultured endothelial monolayers
The DOI matches its Crossref record.
Abstract
To examine the effect of shear stress on hydraulic conductivity (Lp) of bovine aortic endothelial cell monolayers grown on polycarbonate filters, we developed a rotating disk system, which imposed a defined shear stress while Lp was measured. A 10-cmH2O pressure differential was applied to monolayers, and baseline Lp was established between 1.65 +/- 0.85 and 4.94 +/- 1.05 x 10(-7) cm.s-1.cmH2O-1. One-hour exposure to 10 dyn/cm2 shear stress caused a significant (P < 0.05) increase in Lp by 2.16-fold (+/- 0.42), and Lp remained elevated when shear stress was removed. Three-hour exposure to shear stresses between 0.1 and 20.0 dyn/cm2 revealed a threshold for shear-induced increase in Lp of 0.5 dyn/cm2. At 20 dyn/cm2, Lp initially decreased by 30% (+/- 13.4%, P < 0.05) and then increased to a level 3.76-fold (+/- 0.83, P < 0.05) greater than baseline Lp at 3 h. The shear-induced increase in Lp was reversed with dibutyryl adenosine 3',5'-cyclic monophosphate (DBcAMP, 1 mM) and could be significantly (P < 0.05) inhibited when monolayers were preincubated with 0.3 mM DBcAMP, a concentration that did not significantly affect baseline Lp. Furthermore, preincubation with a general phosphodiesterase inhibitor, 3-isobutyl-1-methylxanthine (1 mM), completely blocked the shear-induced increase in Lp. On the basis of these results, we conclude that shear stress alters endothelial Lp through a cellular mechanism involving signal transduction, not by a purely physical mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003) · Circulation Research · doi:10.1161/01.res.0000101744.47866.d5 · Cited by 615
Self-citationShear stress and the endothelial transport barrier
Tarbell, J. M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq146 · Cited by 365
Self-citationMass Transport in Arteries and the Localization of Atherosclerosis
Tarbell, J. M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121529 · Cited by 281
Self-citationSiddharthan, V., Kim, Y. V., Liu, S., & Kim, K. S. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.029 · Cited by 226
“The fluid shear stress strength was calculated according to the formulae: τ =6μQ/a2b, where μ is the viscosity of the perfusate, Q is flow volume (ml/s), a and b is cross sectional dimension of the flow path in centimeters [68].”
MethodMechanically stimulated osteocytes regulate osteoblastic activity via gap junctions
Taylor, A. F., Saunders, M. M., Shingle, D. L., Cimbala, J. M., Zhou, Z., & Donahue, H. J. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00611.2005 · Cited by 220
Buchanan, C. F., Verbridge, S. S., Vlachos, P. P., & Rylander, M. N. (2014) · Cell Adhesion & Migration · doi:10.4161/19336918.2014.970001 · Cited by 205
“These findings are consistent with others showing shear stress-mediated endothelial morphological adaptations(22,38,49-52) and permeability.(14,17,19,21,23,53) The presence of tumor cells also increased Pd relative to endothelial mono-cultures, with a significantly greater Pd under high WSS conditions.”
ResultVascular permeability in ocular disease and the role of tight junctions
Erickson, K. K., Sundstrom, J. M., & Antonetti, D. A. (2007) · Angiogenesis · doi:10.1007/s10456-007-9067-z · Cited by 187
“Elevated hydrostatic pressure across bovine aortic endothelial cells first increases flux, which then decreases over the next 30–60 min reaching a new equilibrium [55, 56].”
BackgroundQiu, Y., & Tarbell, J. M. (2000) · Journal of Vascular Research · doi:10.1159/000025726 · Cited by 174
Self-citationUnderwood, J. L., Murphy, C. G., Chen, J., Franse-Carman, L., Wood, I., Epstein, D. L., & Alvarado, J. A. (1999) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1999.277.2.c330 · Cited by 164
Review: in vitro microvessel models
Bogorad, M. I., DeStefano, J., Karlsson, J., Wong, A. D., Gerecht, S., & Searson, P. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00832h · Cited by 145
Metadata
- Authors
- Sill, H. W., Chang, Y. S., Artman, J. R., Frangos, J. A., Hollis, T. M., & Tarbell, J. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1995-02-01
- Volume
- 268
- Issue
- 2
- Pages
- H535-H543
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2414476771
- Cited by
- 155
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.