The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Abstract
The objective of this study was to test whether a glycosaminoglycan component of the surface glycocalyx layer is a fluid shear stress sensor on endothelial cells (ECs). Because enhanced nitric oxide (NO) production in response to fluid shear stress is a characteristic and physiologically important response of ECs, we evaluated NO x (NO 2 − and NO 3 − ) production in response to fluid shear stress after enzymatic removal of heparan sulfate, the dominant glycosaminoglycan of the EC glycocalyx, from cultured ECs. The significant NO x production induced by steady shear stress (20 dyne/cm 2 ) was inhibited completely by pretreatment with 15 mU/mL heparinase III (E.C.4.2.2.8) for 2 hours. Oscillatory shear stress (10±15 dyne/cm 2 ) induced an even greater NO x production than steady shear stress that was completely inhibited by pretreatment with heparinase III. Addition of bradykinin (BK) induced significant NO x production that was not inhibited by heparinase pretreatment, demonstrating that the cells were still able to produce abundant NO after heparinase treatment. Fluorescent imaging with a heparan sulfate antibody revealed that heparinase III treatments removed a substantial fraction of the heparan sulfate bound to the surfaces of ECs. In summary, these experiments demonstrate that a heparan sulfate component of the EC glycocalyx participates in mechanosensing that mediates NO production in response to shear stress. The full text of this article is available online at http://www.circresaha.org.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Osteocytes: master orchestrators of bone
Schaffler, M. B., Cheung, W.-Y., Majeska, R., & Kennedy, O. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9790-y · Cited by 514
Balligand, J.-L., Feron, O., & Dessy, C. (2009) · Physiological Reviews · doi:10.1152/physrev.00042.2007 · Cited by 477
The endothelial glycocalyx: a review of the vascular barrier
Alphonsus, C. S., & Rodseth, R. N. (2014) · Anaesthesia · doi:10.1111/anae.12661 · Cited by 460
Therapeutic strategies targeting the endothelial glycocalyx: acute deficits, but great potential
Becker, B. F., Chappell, D., Bruegger, D., Annecke, T., & Jacob, M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq137 · Cited by 438
Metadata
- Authors
- Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M.
- Venue
- Circulation Research
- Published
- 2003-11-14
- Volume
- 93
- Issue
- 10
- Pages
- e136-42
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2153479733
- Cited by
- 615
- References
- 1
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells. https://app.cochat.ai/papers/10.1161/01.res.0000101744.47866.d5
- The paper
- Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003). Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells. Circulation Research. https://doi.org/10.1161/01.res.0000101744.47866.d5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.