The DOI matches its Crossref record.
Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound
Abstract
Flow-mediated brachial artery vasoactivity has been recently proposed as a noninvasive means for assessing endothelial function. To better characterize this technique, we measured brachial artery diameter and flow using 7.5-MHz ultrasound following 1, 3, and 5 min of upper arm blood pressure cuff occlusion in 19 normal volunteers and 13 patients with coronary artery disease (CAD). Although similar flow increases were observed with each protocol, statistically significant vasodilatation (12.6 +/- 5.7%) was observed in the normals only after 5 min of occlusion. With the use of this protocol, postocclusion blood flow increased 528 +/- 271 and 481 +/- 247% in the normals and CAD patients, respectively (P = NS). More vasodilatation was observed in the normals compared with the CAD patients (11.3 +/- 5.4 vs. 1.6 +/- 5.2%, P < 0.001). Interestingly, vasodilatation persisted for 20 min despite return of blood flow to baseline in 2 min. With the use of lower arm occlusion, arterial diameter was found to decrease 4.4 +/- 3.9% in response to a 85 +/- 7% decrease in flow. We conclude that 1) longer brachial artery occlusion results in more vasodilatation despite similar hyperemic responses, 2) vasodilatation persists substantially beyond hyperemia, and 3) CAD patients have impaired flow-mediated vasodilatation using this noninvasive technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Corretti, M. C., Anderson, T. J., Benjamin, E. J., Celermajer, D., Charbonneau, F., Creager, M. A., Deanfield, J., Drexler, H., Gerhard-Herman, M., Herrington, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01746-6 · Cited by 4,604
Self-citationCeriello, A., Esposito, K., Piconi, L., Ihnat, M. A., Thorpe, J. E., Testa, R., Boemi, M., & Giugliano, D. (2008) · Diabetes · doi:10.2337/db08-0063 · Cited by 1,310
Greenland (2000) · doi:10.1161/01.cir.101.1.e16 · Cited by 924
Effect of a single high-fat meal on endothelial function in healthy subjects
Vogel, R. A., Corretti, M. C., & Plotnick, G. D. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00760-6 · Cited by 798
Self-citationKawano, H., Motoyama, T., Hirashima, O., Hirai, N., Miyao, Y., Sakamoto, T., Kugiyama, K., Ogawa, H., & Yasue, H. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00168-0 · Cited by 676
Metadata
- Authors
- Corretti, M. C., Plotnick, G. D., & Vogel, R. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1995-04-01
- Volume
- 268
- Issue
- 4
- Pages
- H1397-H1404
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1845594264
- Cited by
- 282
- References
- 0
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound. https://app.cochat.ai/papers/10.1152/ajpheart.1995.268.4.h1397
- The paper
- Corretti, M. C., Plotnick, G. D., & Vogel, R. A. (1995). Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1995.268.4.h1397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.