The DOI matches its Crossref record.
Effects of aging on 24-h dynamic baroreceptor control of heart rate in ambulant subjects
Abstract
The effects of aging on the dynamic modulation of baroreflex sensitivity over 24 h was assessed in eight elderly (mean age +/- SD, 63.9 +/- 3.2 yr) and in eight young (23.9 +/- 6.1 yr) mild or moderate essential hypertensive patients, who were subject to a 24-h intra-arterial (Oxford technique) blood pressure recording in ambulatory conditions. The sensitivity of baroreflex control of the heart rate was dynamically assessed by quantifying 1) the slope of the regression line between pulse interval (the reciprocal of heart rate) and systolic blood pressure changes over spontaneously occurring hypertension-bradycardia or hypotension-tachycardia sequences (time domain analysis) and 2) the ratio between spectral-powers of pulse interval and systolic blood pressure around 0.1 Hz (alpha-coefficient: frequency domain analysis). The 24-h average sequence slope was lower in old than in young individuals (4.4 +/- 0.5 vs. 9.9 +/- 1.3 and 4.8 +/- 0.7 vs. 8.4 +/- 1.4 ms/mmHg for hypertension-bradycardia and hypotension-tachycardia sequences, respectively; P < 0.05 for both). Similar results were obtained by using the alpha-coefficient approach. The marked nighttime increase in baroreflex sensitivity observed in young individuals was much less evident in the elderly. Thus 24-h baroreflex sensitivity is markedly impaired by aging. The impairment becomes manifest also as an inability to increase baroreflex sensitivity at night.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adrenergic and Muscarinic Receptors in the Human Heart
Brodde, O.-E., & Michel, M. C. (1999) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01425-x · Cited by 673
Baroreflex Sensitivity: Measurement and Clinical Implications
La Rovere, M. T., Pinna, G. D., & Raczak, G. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00219.x · Cited by 659
How to measure baroreflex sensitivity: from the cardiovascular laboratory to daily life
Parati, G., Di Rienzo, M., & Mancia, G. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018010-00003 · Cited by 516
Self-citationLaude, D., Elghozi, J.-L., Girard, A., Bellard, E., Bouhaddi, M., Castiglioni, P., Cerutti, C., Cividjian, A., Di Rienzo, M., Fortrat, J.-O., et al. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00709.2002 · Cited by 402
Self-citationInvited Review: Aging and the cardiovascular system
Ferrari, A. U., Radaelli, A., & Centola, M. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00601.2003 · Cited by 382
Metadata
- Authors
- Parati, G., Frattola, A., Di Rienzo, M., Castiglioni, P., Pedotti, A., & Mancia, G.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1995-04-01
- Volume
- 268
- Issue
- 4
- Pages
- H1606-H1612
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2220436017
- Cited by
- 164
- References
- 0
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of aging on 24-h dynamic baroreceptor control of heart rate in ambulant subjects. https://app.cochat.ai/papers/10.1152/ajpheart.1995.268.4.h1606
- The paper
- Parati, G., Frattola, A., Di Rienzo, M., Castiglioni, P., Pedotti, A., & Mancia, G. (1995). Effects of aging on 24-h dynamic baroreceptor control of heart rate in ambulant subjects. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1995.268.4.h1606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.