The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study)
Abstract
This study compared spontaneous baroreflex sensitivity (BRS) estimates obtained from an identical set of data by 11 European centers using different methods and procedures. Noninvasive blood pressure (BP) and ECG recordings were obtained in 21 subjects, including 2 subjects with established baroreflex failure. Twenty-one estimates of BRS were obtained by methods including the two main techniques of BRS estimates, i.e., the spectral analysis (11 procedures) and the sequence method (7 procedures) but also one trigonometric regressive spectral analysis method (TRS), one exogenous model with autoregressive input method (X-AR), and one Z method. With subjects in a supine position, BRS estimates obtained with calculations of α-coefficient or gain of the transfer function in both the low-frequency band or high-frequency band, TRS, and sequence methods gave strongly related results. Conversely, weighted gain, X-AR, and Z exhibited lower agreement with all the other techniques. In addition, the use of mean BP instead of systolic BP in the sequence method decreased the relationships with the other estimates. Some procedures were unable to provide results when BRS estimates were expected to be very low in data sets (in patients with established baroreflex failure). The failure to provide BRS values was due to setting of algorithmic parameters too strictly. The discrepancies between procedures show that the choice of parameters and data handling should be considered before BRS estimation. These data are available on the web site ( http://www.cbi.polimi.it/glossary/eurobavar.html ) to allow the comparison of new techniques with this set of results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
The Value of Cardiovascular Autonomic Function Tests: 10 Years Experience in Diabetes
Ewing, D. J., Martyn, C. N., Young, R. J., & Clarke, B. F. (1985) · Diabetes Care · doi:10.2337/diacare.8.5.491 · Cited by 1,434
SMYTH, H. S., SLEIGHT, P., & PICKERING, G. W. (1969) · Circulation Research · doi:10.1161/01.res.24.1.109 · Cited by 1,282
Assessment of baroreceptor reflex sensitivity by means of spectral analysis.
Robbe, H. W., Mulder, L. J., Rüddel, H., Langewitz, W. A., Veldman, J. B., & Mulder, G. (1987) · Hypertension · doi:10.1161/01.hyp.10.5.538 · Cited by 746
Changes in autonomic regulation induced by physical training in mild hypertension.
Pagani, M., Somers, V, Furlan, R., Dell'Orto, S., Conway, J., Baselli, G., Cerutti, S., Sleight, P., & Malliani, A. (1988) · Hypertension · doi:10.1161/01.hyp.12.6.600 · Cited by 745
La Rovere, M. T., Specchia, G., Mortara, A., & Schwartz, P. J. (1988) · Circulation · doi:10.1161/01.cir.78.4.816 · Cited by 631
Parati, G., Di Rienzo, M., Bertinieri, G., Pomidossi, G., Casadei, R., Groppelli, A., Pedotti, A., Zanchetti, A., & Mancia, G. (1988) · Hypertension · doi:10.1161/01.hyp.12.2.214 · Cited by 616
Self-citationEvaluation of baroreceptor reflex by blood pressure monitoring in unanesthetized cats
Bertinieri, G., DiRienzo, M., Cavallazzi, A., Ferrari, A. U., Pedotti, A., & Mancia, G. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.255.6.1-a · Cited by 300
Self-citationEvaluation of baroreceptor reflex by blood pressure monitoring in unanesthetized cats
Bertinieri, G., Di Rienzo, M., Cavallazzi, A., Ferrari, A. U., Pedotti, A., & Mancia, G. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.2.h377 · Cited by 241
Self-citationPorta, A., Baselli, G., Rimoldi, O., Malliani, A., & Pagani, M. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.5.h2558 · Cited by 197
Self-citation
Cited by
Heart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820
Parati, G., Mancia, G., Rienzo, M. D., & Castiglioni, P. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00446.2006 · Cited by 325
Self-citationTime-domain cross-correlation baroreflex sensitivity: performance on the EUROBAVAR data set
Westerhof, B. E., Gisolf, J., Stok, W. J., Wesseling, K. H., & Karemaker, J. M. (2004) · Journal of Hypertension · doi:10.1097/01.hjh.0000125439.28861.ed · Cited by 258
Self-citationSympathetic control of short-term heart rate variability and its pharmacological modulation.
Elghozi, J., & Julien, C. (2007) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2007.00502.x · Cited by 97
Self-citationKlingenheben, T., Ptaszynski, P., & Hohnloser, S. H. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.10.004 · Cited by 32
Metadata
- Authors
- Laude, D., Elghozi, J.-L., Girard, A., Bellard, E., Bouhaddi, M., Castiglioni, P., Cerutti, C., Cividjian, A., Di Rienzo, M., Fortrat, J.-O., Janssen, B., Karemaker, J. M., Lefthériotis, G., Parati, G., Persson, P. B., Porta, A., Quintin, L., Regnard, J., Rüdiger, H., & Stauss, H. M.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2004-01
- Volume
- 286
- Issue
- 1
- Pages
- R226-R231
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2144867752
- Cited by
- 402
- References
- 16
- FWCI
- 14.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). https://app.cochat.ai/papers/10.1152/ajpregu.00709.2002
- The paper
- Laude, D., Elghozi, J.-L., Girard, A., Bellard, E., Bouhaddi, M., Castiglioni, P., Cerutti, C., Cividjian, A., Di Rienzo, M., Fortrat, J.-O., Janssen, B., Karemaker, J. M., Lefthériotis, G., Parati, G., Persson, P. B., Porta, A., Quintin, L., Regnard, J., Rüdiger, H., & Stauss, H. M. (2004). Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.00709.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.