CoChat

High muscle blood flows are not attenuated by recruitment of additional muscle mass

Richardson, R. S., Kennedy, B., Knight, D. R., Wagner, P. D. · 1995 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 69

The DOI matches its Crossref record.

Abstract

Recent studies have demonstrated that single-leg knee extensor (KE) exercise elicits high mass-specific blood flow (Q) which, if incremented toward maximum, in the presence of additional muscle recruitment would soon outstrip the heart's pumping capacity and blood pressure would fall. Thus incremental KE exercise provides the opportunity to determine the intensity at which, if at all, quadriceps muscle hemodynamics are altered during incremental exercise that involves a substantially greater muscle mass. Leg Q was measured during incremental KE exercise and again with superimposed incremental two-legged knee extensor exercise with incremental arm cranking (A+L) in trained subjects (n = 5). Leg Q and vascular conductance (VC) increased with work rate (WR) to reach high levels [Q = 385.7 +/- 26 and 342.3 +/- 15 ml.min-1.100 g-1 for KE and A+L exercise, respectively; VC at 90% of maximum WR (WRmax) = 79 +/- 5 and 75 +/- 6 ml.min-1. mmHg-1 for KE and A+L exercise, respectively], but the Q/WR and VC/WR relationships in KE and A+L exercise were not different. Maximum O2 consumption (VO2max) and the VO2max/WR relationship of the quadriceps were also unaffected by the additional muscle mass recruited. Despite a significantly greater net femoral venous norepinephrine (NE) outflow at both 90 and 100% of WRmax in A+L exercise (WRmax = 4,216 +/- 1,601 and 901 +/- 99 ng/ml for A+L and KE exercise, respectively; P < 0.05), leg Q continued to rise linearly with WR.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1995.269.5.h1545

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
Richardson, R. S., Kennedy, B., Knight, D. R., & Wagner, P. D.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1995-11-01
Volume
269
Issue
5
Pages
H1545-H1552
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2274828467
Cited by
69
References
0
FWCI
6.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High muscle blood flows are not attenuated by recruitment of additional muscle mass. https://app.cochat.ai/papers/10.1152/ajpheart.1995.269.5.h1545
The paper
Richardson, R. S., Kennedy, B., Knight, D. R., & Wagner, P. D. (1995). High muscle blood flows are not attenuated by recruitment of additional muscle mass. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1995.269.5.h1545

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.