CoChat

Flow velocity of single lymphatic capillaries in human skin

Fischer, M., Franzeck, U. K., Herrig, I., Costanzo, U., Wen, S., Schiesser, M., Hoffmann, U., Bollinger, A. · 1996 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 78

The DOI matches its Crossref record.

Abstract

The purpose of this study was to investigate the previously unknown flow velocity in single lymphatic capillaries of humans in the supine position. Fifteen healthy subjects (10 women and 5 men; mean age 35.8 +/- 13.1 yr) were studied. Ten microliters of fluorescein isothiocyanate-dextran (150,000 mol wt) were injected into the subepidermal layer of the foot dorsum. The filling of the microlymphatics from the resulting depot was visualized by fluorescence video microscopy and stored on videotape. Flow velocity in the microlymphatics was determined on the video screen by direct measurement of the advancement of dyed lymph during a given time. The following median velocities were obtained: 0.51 mm/s (0.27 and 0.61 mm/s for lower and upper quartiles, respectively) for velocity during initial network filling and 9.7 microns/s (6.9 and 14.2 microns/s for lower and upper quartiles, respectively) for resting velocity at the end of the filling period. Mean lymphatic capillary diameter was 54.8 +/- 8.2 microns, and mean network extension was 8.3 +/- 3.2 mm. The high filling velocities are probably due to increased interstitial pressure and volume caused by dye microinjection, whereas the values measured during the end of network filling seem to approach resting flow velocities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1996.270.1.h358

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 78

Metadata

Authors
Fischer, M., Franzeck, U. K., Herrig, I., Costanzo, U., Wen, S., Schiesser, M., Hoffmann, U., & Bollinger, A.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1996-01-01
Volume
270
Issue
1
Pages
H358-H363
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2140924919
Cited by
78
References
0
FWCI
0.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow velocity of single lymphatic capillaries in human skin. https://app.cochat.ai/papers/10.1152/ajpheart.1996.270.1.h358
The paper
Fischer, M., Franzeck, U. K., Herrig, I., Costanzo, U., Wen, S., Schiesser, M., Hoffmann, U., & Bollinger, A. (1996). Flow velocity of single lymphatic capillaries in human skin. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1996.270.1.h358

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.