Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics

DIXON, J. BRANDON, GREINER, STEVEN T., GASHEV, ANATOLIY A., COTE, GERARD L., MOORE, JAMES E., ZAWIEJA, DAVID C.·2006·Microcirculation

Abstract

Objective: To measure lymphocyte velocity, lymphatic contraction, and shear stress in phasically contracting lymphatics in situ. Methods: A high‐speed video system was used to capture multiple contraction cycles in rat mesenteric lymphatic preparations. The images were analyzed to determine fluid velocity, volume flow rate, wall shear stress, and retrograde flow. Results: Lymphocyte density and flux varied from 326 to 35,500 cells/μ L and 206 to 2030 cells/min, respectively. Lymphatics contracted phasically, with a mean diameter 91 ± 9.0 μ m and amplitudes of 39%. Lymph velocity varied with the phasic contractions in both direction and magnitude with an average of 0.87 ± 0.18 and peaks of 2.2–9.0 mm/s. The velocity was ∼ 180° out of phase with the contraction cycle. The average lymph flow was 13.95 ± 5.27 μ L/h with transient periods of flow reversal. This resulted in an average shear of 0.64 ± 0.14 with peaks of 4–12 dynes/cm 2. Conclusions: High‐speed lymphocyte tracking provided the spatial and temporal resolution to measure lymphocyte flux throughout the phasic contraction. Poiseuille flow was a reasonable model for estimating wall shear stress through most of the phasic contraction cycle of the intervalvular lymphatic segments. Shear rate was low but had large variations in magnitude compared to that seen in blood vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10739680600893909

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 267

Metadata

Authors
DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C.
Venue
Microcirculation
Publisher
Wiley
Published
2006-10-11
Volume
13
Issue
7
Pages
597-610
ISSN
  • 1073-9688 (ISSN-L)
  • 1549-8719
OpenAlex
W2118722193
Cited by
267
References
3
FWCI
2.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics. https://app.cochat.ai/papers/10.1080/10739680600893909
The paper
DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C. (2006). Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics. Microcirculation. https://doi.org/10.1080/10739680600893909

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.