The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
Abstract
Objective: To measure lymphocyte velocity, lymphatic contraction, and shear stress in phasically contracting lymphatics in situ. Methods: A high‐speed video system was used to capture multiple contraction cycles in rat mesenteric lymphatic preparations. The images were analyzed to determine fluid velocity, volume flow rate, wall shear stress, and retrograde flow. Results: Lymphocyte density and flux varied from 326 to 35,500 cells/μ L and 206 to 2030 cells/min, respectively. Lymphatics contracted phasically, with a mean diameter 91 ± 9.0 μ m and amplitudes of 39%. Lymph velocity varied with the phasic contractions in both direction and magnitude with an average of 0.87 ± 0.18 and peaks of 2.2–9.0 mm/s. The velocity was ∼ 180° out of phase with the contraction cycle. The average lymph flow was 13.95 ± 5.27 μ L/h with transient periods of flow reversal. This resulted in an average shear of 0.64 ± 0.14 with peaks of 4–12 dynes/cm 2. Conclusions: High‐speed lymphocyte tracking provided the spatial and temporal resolution to measure lymphocyte flux throughout the phasic contraction. Poiseuille flow was a reasonable model for estimating wall shear stress through most of the phasic contraction cycle of the intervalvular lymphatic segments. Shear rate was low but had large variations in magnitude compared to that seen in blood vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Intrinsic contractility of prenodal lymph vessels and lymph flow in human leg
Olszewski, W. L., & Engeset, A. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.6.h775 · Cited by 201
Nitric oxide decreases pacemaker activity in lymphatic vessels of guinea pig mesentery
von der Weid, P.-Y., Zhao, J., & Van Helden, D. F. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2707 · Cited by 111
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Sabine, A., Agalarov, Y., Maby-El Hajjami, H., Jaquet, M., Hägerling, R., Pollmann, C., Bebber, D., Pfenniger, A., Miura, N., Dormond, O., et al. (2012) · Developmental Cell · doi:10.1016/j.devcel.2011.12.020 · Cited by 411
Chronic stress in mice remodels lymph vasculature to promote tumour cell dissemination
Le, C. P., Nowell, C. J., Kim-Fuchs, C., Botteri, E., Hiller, J. G., Ismail, H., Pimentel, M. A., Chai, M. G., Karnezis, T., Rotmensz, N., et al. (2016) · Nature Communications · doi:10.1038/ncomms10634 · Cited by 354
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137301 · Cited by 124
Metadata
- Authors
- DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2006-10-11
- Volume
- 13
- Issue
- 7
- Pages
- 597-610
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2118722193
- Cited by
- 267
- References
- 3
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics. https://app.cochat.ai/papers/10.1080/10739680600893909
- The paper
- DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C. (2006). Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics. Microcirculation. https://doi.org/10.1080/10739680600893909
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.