Valsalva's maneuver revisited: a quantitative method yielding insights into human autonomic control
The DOI matches its Crossref record.
Abstract
Seventeen healthy supine subjects performed graded Valsalva maneuvers. In four subjects, transesophageal echographic aortic cross-sectional areas decreased during and increased after straining. During the first seconds of straining, when aortic cross-sectional area was declining and peripheral arterial pressure was rising, peroneal sympathetic muscle neurons were nearly silent. Then, as aortic cross-sectional area and peripheral pressure both declined, sympathetic muscle nerve activity increased, in proportion to the intensity of straining. Poststraining arterial pressure elevations were proportional to preceding increases of sympathetic activity. Sympathetic inhibition after straining persisted much longer than arterial and right atrial pressure elevations. Similarly, R-R intervals changed in parallel with peripheral arterial pressure, until approximately 45 s after the onset of straining, when R-R intervals were greater and arterial pressures were smaller than prestraining levels. Our conclusions are as follows: opposing changes of carotid and aortic baroreceptor inputs reduce sympathetic muscle and increase vagal cardiac motor neuronal firing; parallel changes of barorsensory inputs provoke reciprocal changes of sympathetic and direct changes of vagal firing; and pressure transients lasting only seconds reset arterial pressure-sympathetic and -vagal response relations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Willie, C. K., Colino, F. L., Bailey, D. M., Tzeng, Y. C., Binsted, G., Jones, L. W., Haykowsky, M. J., Bellapart, J., Ogoh, S., Smith, K. J., et al. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.01.011 · Cited by 546
Autonomic Neural Control of Dynamic Cerebral Autoregulation in Humans
Zhang, R., Zuckerman, J. H., Iwasaki, K., Wilson, T. E., Crandall, C. G., & Levine, B. D. (2002) · Circulation · doi:10.1161/01.cir.0000031798.07790.fe · Cited by 469
Human sympathetic and vagal baroreflex responses to sequential nitroprusside and phenylephrine
Rudas, L., Crossman, A. A., Morillo, C. A., Halliwill, J. R., Tahvanainen, K. U. O., Kuusela, T. A., & Eckberg, D. L. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.5.h1691 · Cited by 294
Self-citationAssessment of cardiovascular autonomic function
Freeman, R. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.027 · Cited by 262
Monahan, K. D., Dinenno, F. A., Seals, D. R., Clevenger, C. M., Desouza, C. A., & Tanaka, H. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.1.h284 · Cited by 241
Stewart, J. M. (2000) · Pediatric Research · doi:10.1203/00006450-200008000-00016 · Cited by 198
Human muscle sympathetic neural and haemodynamic responses to tilt following spaceflight
Levine, B. D., Pawelczyk, J. A., Ertl, A. C., Cox, J. F., Zuckerman, J. H., Diedrich, A., Biaggioni, I., Ray, C. A., Smith, M. L., Iwase, S., et al. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012575 · Cited by 191
Self-citationThe Valsalva manoeuvre: physiology and clinical examples
Pstras, L., Thomaseth, K., Waniewski, J., Balzani, I., & Bellavere, F. (2016) · Acta Physiologica · doi:10.1111/apha.12639 · Cited by 188
“However, the activity of carotid baroreceptors seems to have priority over the aortic baroreceptors (Smith et al. 1996).”
BackgroundMonahan, K. D., Dinenno, F. A., Tanaka, H., Clevenger, C. M., DeSouza, C. A., & Seals, D. R. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00263.x · Cited by 184
“For both studies, we measured cardiovagal BRS using Valsalva’s manoeuvre (Eckberg & Sleight, 1992; Smith et al. 1996) because it: (1) is non-invasive and, thus, appropriate for use in older adults; (2) provides results that correlate strongly with invasive (‘gold standard’) techniques (Palmero et…”
BackgroundMethodInfluentialMethods of assessing vagus nerve activity and reflexes
Chapleau, M. W., & Sabharwal, R. (2011) · Heart Failure Reviews · doi:10.1007/s10741-010-9174-6 · Cited by 182
“The test is relatively simple to perform, does not require extensive equipment, and results are reproducible within a given subject [39, 46, 47].”
BackgroundTesting the autonomic nervous system
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52902-2.00007-2 · Cited by 161
Wen, Z.-C., Chen, S.-A., Tai, C.-T., Chiang, C.-E., Chiou, C.-W., & Chang, M.-S. (1998) · Circulation · doi:10.1161/01.cir.98.24.2716 · Cited by 101
Assessment of sympathetic index from the Valsalva maneuver
Novak, P. (2011) · Neurology · doi:10.1212/wnl.0b013e31821e5563 · Cited by 88
Metadata
- Authors
- Smith, M. L., Beightol, L. A., Fritsch-Yelle, J. M., Ellenbogen, K. A., Porter, T. R., & Eckberg, D. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1996-09-01
- Volume
- 271
- Issue
- 3
- Pages
- H1240-H1249
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1761001101
- Cited by
- 112
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.