A treadmill exercise regimen for identifying cardiovascular phenotypes in transgenic mice
The DOI matches its Crossref record.
Abstract
Cardiovascular stress in response to treadmill exercise is frequently used to detect cardiac abnormalities that are not readily apparent at rest. Herein we describe a treadmill exercise protocol for mice that allows for quantitation of the performance of an animal and the ability to gather metabolic information in a nonrestraining manner using telemetry implant devices. Transgenic (TG) mice overexpressing ventricular myosin regulatory light chain (MLC2v) were subjected to a 5-wk exercise regimen. The TG mice had significant decreases in their capacity for exercise at relatively high treadmill speeds compared with their nontransgenic (NTG) littermates. There was no indication of a hypertrophic response occurring in TG or NTG animals in response to the exercise protocol, and exercise had no effect on MLC2v phosphorylation. Ultrastructural examination of TG atria showed overtly normal myofibrillar organization but a proliferation of the transverse-axial tubular system. This exercise protocol should prove useful in detecting subtle phenotypes that occur in mice as a result of genetic manipulation of the cardiac compartment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Novel and Efficient Model of Coronary Artery Ligation and Myocardial Infarction in the Mouse
Gao, E., Lei, Y. H., Shang, X., Huang, Z. M., Zuo, L., Boucher, M., Fan, Q., Chuprun, J. K., Ma, X. L., & Koch, W. J. (2010) · Circulation Research · doi:10.1161/circresaha.110.223925 · Cited by 760
Small and large animal models in cardiac contraction research: advantages and disadvantages
Milani-Nejad, N., & Janssen, P. M. L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.007 · Cited by 484
Extracellular Matrix Remodeling and Organization in Developing and Diseased Aortic Valves
Hinton, R. B., Lincoln, J., Deutsch, G. H., Osinska, H., Manning, P. B., Benson, D. W., & Yutzey, K. E. (2006) · Circulation Research · doi:10.1161/01.res.0000224114.65109.4e · Cited by 448
Self-citationCardiac and skeletal muscle adaptations to voluntary wheel running in the mouse
Allen, D. L., Harrison, B. C., Maass, A., Bell, M. L., Byrnes, W. C., & Leinwand, L. A. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1900 · Cited by 376
Disruption of the Sarcoglycan–Sarcospan Complex in Vascular Smooth Muscle
Coral-Vazquez, R., Cohn, R. D., Moore, S. A., Hill, J. A., Weiss, R. M., Davisson, R. L., Straub, V., Barresi, R., Bansal, D., Hrstka, R. F., et al. (1999) · Cell · doi:10.1016/s0092-8674(00)81975-3 · Cited by 371
Metadata
- Authors
- Fewell, J. G., Osinska, H., Klevitsky, R., Ng, W., Sfyris, G., Bahrehmand, F., & Robbins, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1997-09-01
- Volume
- 273
- Issue
- 3
- Pages
- H1595-H1605
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2113464960
- Cited by
- 97
- References
- 0
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A treadmill exercise regimen for identifying cardiovascular phenotypes in transgenic mice. https://app.cochat.ai/papers/10.1152/ajpheart.1997.273.3.h1595
- The paper
- Fewell, J. G., Osinska, H., Klevitsky, R., Ng, W., Sfyris, G., Bahrehmand, F., & Robbins, J. (1997). A treadmill exercise regimen for identifying cardiovascular phenotypes in transgenic mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1997.273.3.h1595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.