Positive force- and [Ca2+]i-frequency relationships in rat ventricular trabeculae at physiological frequencies
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The isometric force-frequency relationship of isolated rat ventricular trabeculae (diameter <250 μm) was examined at 24, 30, and 37°C at stimulation frequencies (0.1–12 Hz) encompassing the physiological range. Some muscles were microinjected with fura PE3 to monitor the diastolic and systolic intracellular concentration of Ca 2+([Ca 2+]i). At a near-physiological external Ca 2+concentration ([Ca 2+]o) of 1 mM, a positive force-frequency relationship was demonstrated at all temperatures. The force-frequency relationship became negative at high frequencies (e.g., >6 Hz at 30°C) at 1 mM [Ca 2+]o or at low frequencies at 8 mM [Ca 2+]o. The twitch and Ca 2+transient became shorter as stimulation frequency increased; these changes were related to changes in systolic, rather than diastolic, [Ca 2+]i and were not blocked by inhibitors of Ca 2+/calmodulin-dependent protein kinase II. The positive force-frequency relationship of rat trabeculae was caused by a frequency-dependent loading of the sarcoplasmic reticulum (SR) with Ca 2+. We suggest that at high frequencies, or under conditions of Ca 2+overload, this loading saturates. Processes that tend to decrease SR Ca 2+release will then predominate, resulting in a negative force-frequency relationship.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, L., Chu, G., Kranias, E. G., & Bers, D. M. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.4.h1335 · Cited by 222
Cited by
Calcium Cycling and Signaling in Cardiac Myocytes
Bers, D. M. (2008) · Annual Review of Physiology · doi:10.1146/annurev.physiol.70.113006.100455 · Cited by 1,302
Maier, L. S., Zhang, T., Chen, L., DeSantiago, J., Brown, J. H., & Bers, D. M. (2003) · Circulation Research · doi:10.1161/01.res.0000069685.20258.f1 · Cited by 433
Maier, L. S., & Bers, D. M. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.11.005 · Cited by 330
Calcium, Calmodulin, and Calcium-Calmodulin Kinase II: Heartbeat to Heartbeat and Beyond
Maier, L. S., & Bers, D. M. (2002) · Journal of Molecular and Cellular Cardiology · doi:10.1006/jmcc.2002.2038 · Cited by 309
Endoh, M. (2004) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2004.07.013 · Cited by 250
Metadata
- Authors
- Layland, J., & Kentish, J. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1999-01-01
- Volume
- 276
- Issue
- 1
- Pages
- H9-H18
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W115989438
- Cited by
- 132
- References
- 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Positive force- and [Ca2+]i-frequency relationships in rat ventricular trabeculae at physiological frequencies. https://app.cochat.ai/papers/10.1152/ajpheart.1999.276.1.h9
- The paper
- Layland, J., & Kentish, J. C. (1999). Positive force- and [Ca2+]i-frequency relationships in rat ventricular trabeculae at physiological frequencies. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1999.276.1.h9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.