Capillary endothelial surface layer selectively reduces plasma solute distribution volume
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
We previously reported that a 0.4- to 0.5-μm-thick endothelial surface layer confines Dextran 70 (70 kDa) to the central core of hamster cremaster muscle capillaries. In the present study we used a variety of plasma tracers to probe the barrier properties of the endothelial surface layer using combined fluorescence and brightfield intravital microscopy. No permeation of the endothelial surface layer was observed for either neutral or anionic dextrans ≥70 kDa, but a neutral Dextran 40 (40 kDa) and neutral free dye (rhodamine, 0.4 kDa) equilibrated with the endothelial surface layer within 1 min. In contrast, small anionic tracers of similar size (0.4–40 kDa) permeated the endothelial surface layer relatively slowly with half-times (τ 50) between 11 and 60 min, depending on tracer size. Furthermore, two plasma proteins, fibrinogen (340 kDa) and albumin (67 kDa), moved slowly into the endothelial surface layer at the same rates, despite greatly differing sizes (τ 50 ≈ 40 min). Dextran 70, which did not enter the glycocalyx over the course of these experiments, entered at the same rate as free albumin when it was conjugated to albumin. These findings demonstrate that for anionic molecules size and charge have a profound effect on the penetration rate into the glycocalyx. The equal rates of penetration of the glycocalyx demonstrated by the different protein molecules suggests that multiple factors may influence the penetration of the barrier, including molecular size, charge, and structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEOGLYCANS: STRUCTURES AND INTERACTIONS
Kjellén, L., & Lindahl, U. (1991) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.60.070191.002303 · Cited by 1,719
Proteoglycans: Structures And Interactions
Kjellen, L. (1991) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.60.1.443 · Cited by 1,594
Pappenheimer, J. R., Renkin, E. M., & Borrero, L. M. (1951) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1951.167.1.13 · Cited by 977
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Self-citationFine structures of capillary and endocapillary layer as revealed by ruthenium red.
Luft, J. H. (1966) · PubMed · Cited by 504
A fiber matrix model of capillary permeability
Curry, F. E., & Michel, C. C. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90024-2 · Cited by 391
Structure and function of the glycocalyx.
Ito, S. (1969) · PubMed · Cited by 208
An analysis of the permeability of a fenestra
Levick, J. R., & Smaje, L. H. (1987) · Microvascular Research · doi:10.1016/0026-2862(87)90020-3 · Cited by 142
Single capillary permeability to proteins having similar size but different charge
Adamson, R. H., Huxley, V. H., & CURRY, F. E. (1988) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1988.254.2.h304 · Cited by 76
Vink, H., Wieringa, P. A., & Spaan, J. A. E. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp021041 · Cited by 25
Self-citation
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Self-citationSignaling Mechanisms Regulating Endothelial Permeability
Mehta, D., & Malik, A. B. (2006) · Physiological Reviews · doi:10.1152/physrev.00012.2005 · Cited by 1,720
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Properties of the Glomerular Barrier and Mechanisms of Proteinuria
Haraldsson, B., Nyström, J., & Deen, W. M. (2008) · Physiological Reviews · doi:10.1152/physrev.00055.2006 · Cited by 909
Metadata
- Authors
- Vink, H., & Duling, B. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-01-01
- Volume
- 278
- Issue
- 1
- Pages
- H285-H289
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2162551249
- Cited by
- 335
- References
- 10
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.