CoChat

Transient increases in diameter and [Ca2+]i are not obligatory for myogenic constriction

Hill, Michael A., Zou, Hui, Davis, Michael J., Potocnik, Simon J., Price, Simone · 2000 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 59

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Studies were performed to determine the significance of temporal variation in vascular smooth muscle Ca 2+ signaling during acute arteriolar myogenic constriction and, in particular, the importance of the stretch-induced intracellular Ca 2+concentration ([Ca 2+]i) transient in attaining a steady-state mechanical response. Rat cremaster arterioles (diameter ∼100 μm) were dissected from surrounding tissues, and vessel segments were pressurized in the absence of intraluminal flow. For [Ca 2+]i measurements, vessels were loaded with fura 2 and fluorescence emitted by excitation at 340 and 380 nm was measured using video-based image analysis. Ca 2+ and diameter responses were examined after increases in intravascular pressure were applied as an acute step increase or a ramp function. Additional studies examined the effect of longitudinal vessel stretch on [Ca 2+]i and arteriolar diameter. Step increase in intraluminal pressure (from 50 to 120 mmHg) caused biphasic change in [Ca 2+]i and diameter. [Ca 2+]i transiently increased to 114.0 ± 2.0% of basal levels and subsequently declined to 106.7 ± 4.4% at steady state. Diameter initially distended to 125.4 ± 2.1% of basal levels before constricting to 71.1 ± 1.2%. In contrast, when the same pressure increase was applied as a ramp function (over 5 min) transient vessel distension and transient increase in [Ca 2+]i were prevented, yet at steady state vessels constricted to 71.3 ± 2.5%. Longitudinal stretch resulted in a large [Ca 2+]i transient (158 ± 19% of basal) that returned to baseline despite maintenance of the stretch stimulus. The data demonstrate that the initial vessel distension (reflecting myocyte stretch) and associated global [Ca 2+]i transient are not obligatory for myogenic contraction. Thus, although arteriolar smooth muscle cells are responsive to acute stretch, the resulting changes in myogenic tone may be more closely related to other mechanical variables such as wall tension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.2000.278.2.h345

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Hill, M. A., Zou, H., Davis, M. J., Potocnik, S. J., & Price, S.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2000-02-01
Volume
278
Issue
2
Pages
H345-H352
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W40774793
Cited by
59
References
1
FWCI
3.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.