The DOI matches its Crossref record.
Mathematical models of action potentials in the periphery and center of the rabbit sinoatrial node
Abstract
Mathematical models of the action potential in the periphery and center of the rabbit sinoatrial (SA) node have been developed on the basis of published experimental data. Simulated action potentials are consistent with those recorded experimentally: the model-generated peripheral action potential has a more negative takeoff potential, faster upstroke, more positive peak value, prominent phase 1 repolarization, greater amplitude, shorter duration, and more negative maximum diastolic potential than the model-generated central action potential. In addition, the model peripheral cell shows faster pacemaking. The models behave qualitatively the same as tissue from the periphery and center of the SA node in response to block of tetrodotoxin-sensitive Na+current, L- and T-type Ca 2+ currents, 4-aminopyridine-sensitive transient outward current, rapid and slow delayed rectifying K+ currents, and hyperpolarization-activated current. A one-dimensional model of a string of SA node tissue, incorporating regional heterogeneity, coupled to a string of atrial tissue has been constructed to simulate the behavior of the intact SA node. In the one-dimensional model, the spontaneous action potential initiated in the center propagates to the periphery at ∼0.06 m/s and then into the atrial muscle at 0.62 m/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Self-citationGenesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
Bogdanov, K. Y., Vinogradova, T. M., & Lakatta, E. G. (2001) · Circulation Research · doi:10.1161/hh1201.092095 · Cited by 368
De novo KCNQ1 mutation responsible for atrial fibrillation and short QT syndrome in utero
HONG, K., PIPER, D., DIAZVALDECANTOS, A., BRUGADA, J., OLIVA, A., BURASHNIKOV, E., SANTOSDESOTO, J., GRUESOMONTERO, J., DIAZENFANTE, E., & BRUGADA, P. (2005) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.06.023 · Cited by 306
de Geus, E. J. C., Gianaros, P. J., Brindle, R. C., Jennings, J. R., & Berntson, G. G. (2019) · Psychophysiology · doi:10.1111/psyp.13287 · Cited by 219
Metadata
- Authors
- Zhang, H., Holden, A. V., Kodama, I., Honjo, H., Lei, M., Varghese, T., & Boyett, M. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-07-01
- Volume
- 279
- Issue
- 1
- Pages
- H397-H421
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2155018227
- Cited by
- 341
- References
- 0
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mathematical models of action potentials in the periphery and center of the rabbit sinoatrial node. https://app.cochat.ai/papers/10.1152/ajpheart.2000.279.1.h397
- The paper
- Zhang, H., Holden, A. V., Kodama, I., Honjo, H., Lei, M., Varghese, T., & Boyett, M. R. (2000). Mathematical models of action potentials in the periphery and center of the rabbit sinoatrial node. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2000.279.1.h397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.