Starling forces that oppose filtration after tissue oncotic pressure is increased
The DOI matches its Crossref record.
Abstract
We tested the hypothesis that the effective oncotic force that opposes fluid filtration across the microvessel wall is the local oncotic pressure difference across the endothelial surface glycocalyx and not the global difference between the plasma and tissue. In single frog mesenteric microvessels perfused and superfused with solutions containing 50 mg/ml albumin, the effective oncotic pressure exerted across the microvessel wall was not significantly different from that measured when the perfusate alone contained albumin at 50 mg/ml. Measurements were made during transient and steady-state filtration at capillary pressures between 10 and 35 cmH 2 O. A cellular-level model of coupled water and solute flows in the interendothelial cleft showed water flux through small breaks in the junctional strand limited back diffusion of albumin into the protected space on the tissue side of the glycocalyx. Thus oncotic forces opposing filtration are larger than those estimated from blood-to-tissue protein concentration differences, and transcapillary fluid flux is smaller than estimated from global differences in oncotic and hydrostatic pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationMicrovascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
“When interstitial albumin concentration around rapidly filtering frog mesenteric capillaries was raised by superfusion to equal that perfused through the capillary lumen (Pp 2 Pi 1⁄4 0), there was almost no change in the filtration rate—a finding incompatible with the classic Starling principle but in line with the We…”
ResultA Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Nichols, J. W., & Bae, Y. H. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.057 · Cited by 834
Metadata
- Authors
- Hu, X., Adamson, R. H., Liu, B., Curry, F. E., & Weinbaum, S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-10-01
- Volume
- 279
- Issue
- 4
- Pages
- H1724-H1736
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2177224260
- Cited by
- 143
- References
- 0
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Starling forces that oppose filtration after tissue oncotic pressure is increased. https://app.cochat.ai/papers/10.1152/ajpheart.2000.279.4.h1724
- The paper
- Hu, X., Adamson, R. H., Liu, B., Curry, F. E., & Weinbaum, S. (2000). Starling forces that oppose filtration after tissue oncotic pressure is increased. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2000.279.4.h1724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.