Specific impedance of rabbit's cortical tissue
The DOI matches its Crossref record.
Abstract
The impedance of a tissue slab consisting of both cortical gray and underlying white matter was measured at 1,000 cycles/sec between a surface electrode and a deep electrode placed in the lateral ventricle or in the underlying tissue. By calibrating the electrode assembly with a KCl solution of known conductivity the mean specific impedance of the slab could be computed. Through a hole in the center of the surface electrode a probe was lowered stepwise, and the potential between its tip and the deep electrode was determined after each change in position. In a graph of the potential plotted against the position of the tip, the ratios of the specific impedances of the various layers of tissues in the slab and the thicknesses of these layers could be determined. From these data and the mean specific impedance of the tissue slab the specific impedance of the cortex was computed. The mean value determined in 14 experiments was 208 ± 6 ohms cm. The specific impedance of the white matter was materially greater. Taking into consideration the conductivity of the blood in the vessels the specific impedance of the cortical tissue proper was estimated as 220 ohms cm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 453
Conductivity tensor mapping of the human brain using diffusion tensor MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J. S., & Belliveau, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171473898 · Cited by 432
A STUDY OF EXTRACELLULAR SPACE IN CENTRAL NERVOUS TISSUE BY FREEZE-SUBSTITUTION
Van Harreveld, A., Crowell, J., & Malhotra, S. K. (1965) · The Journal of Cell Biology · doi:10.1083/jcb.25.1.117 · Cited by 412
Elul, R. (1972) · International Review of Neurobiology · doi:10.1016/s0074-7742(08)60333-5 · Cited by 379
Haueisen, J., Ramon, C., Eiselt, M., Brauer, H., & Nowak, H. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605429 · Cited by 302
Specific impedance of cerebral white matter
Nicholson, P. (1965) · Experimental Neurology · doi:10.1016/0014-4886(65)90126-3 · Cited by 263
Electrical Properties of Tissue
Duck, F. A. (1990) · Physical Properties of Tissues · doi:10.1016/b978-0-12-222800-1.50010-3 · Cited by 242
The Influence of Brain Tissue Anisotropy on Human EEG and MEG
Haueisen, J., Tuch, D. S., Ramon, C., Schimpf, P. H., Wedeen, V. J., George, J. S., & Belliveau, J. W. (2002) · NeuroImage · doi:10.1006/nimg.2001.0962 · Cited by 228
“The electrical conductivity of brain tissue, particularly white matter, is known to be anisotropic (Geddes et al., 1967; Nicholson, 1965; Okada et al., 1994; Polk et al., 1986; Ranck, 1963; van Harreveld et al., 1963).”
BackgroundMiranda, P. C., Hallett, M., & Basser, P. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816079 · Cited by 215
“2 [41], [43], some 2 times lower than that of GM.”
Dietzel, I., Heinemann, U., & Lux, H. D. (1989) · Glia · doi:10.1002/glia.440020104 · Cited by 199
The specific impedance of the dorsal columns of cat: An anisotropic medium
Ranck Jr., J. B., & BeMent, S. L. (1965) · Experimental Neurology · doi:10.1016/0014-4886(65)90059-2 · Cited by 185
Predicting the electric field distribution in the brain for the treatment of glioblastoma
Miranda, P. C., Mekonnen, A., Salvador, R., & Basser, P. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/15/4137 · Cited by 131
“59 (2014) 4137 1982, Surowiec et al 1986, Van Harreveld et al 1963, Freygang and Landau 1955), and tumor (Peloso et al 1984, Surowiec et al 1988, Lu et al 1992, Latikka et al 2001).”
BackgroundWenger, C., Salvador, R., Basser, P. J., & Miranda, P. C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/18/7339 · Cited by 121
Metadata
- Authors
- Harreveld, A. V., Murphy, T., & Nobel, K. W.
- Venue
- American Journal of Physiology-Legacy Content
- Publisher
- American Physiological Society
- Published
- 1963-07-01
- Volume
- 205
- Issue
- 1
- Pages
- 203-207
- ISSN
- 0002-9513 (ISSN-L)
- OpenAlex
- W2398610820
- Cited by
- 68
- References
- 0
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.