Predicting the electric field distribution in the brain for the treatment of glioblastoma
Open accessAbstract
The use of alternating electric fields has been recently proposed for the treatment of recurrent glioblastoma. In order to predict the electric field distribution in the brain during the application of such tumor treating fields (TTF), we constructed a realistic head model from MRI data and placed transducer arrays on the scalp to mimic an FDA-approved medical device. Values for the tissue dielectric properties were taken from the literature; values for the device parameters were obtained from the manufacturer. The finite element method was used to calculate the electric field distribution in the brain. We also included a 'virtual lesion' in the model to simulate the presence of an idealized tumor. The calculated electric field in the brain varied mostly between 0.5 and 2.0 V cm( - 1) and exceeded 1.0 V cm( - 1) in 60% of the total brain volume. Regions of local field enhancement occurred near interfaces between tissues with different conductivities wherever the electric field was perpendicular to those interfaces. These increases were strongest near the ventricles but were also present outside the tumor's necrotic core and in some parts of the gray matter-white matter interface. The electric field values predicted in this model brain are in reasonably good agreement with those that have been shown to reduce cancer cell proliferation in vitro. The electric field distribution is highly non-uniform and depends on tissue geometry and dielectric properties. This could explain some of the variability in treatment outcomes. The proposed modeling framework could be used to better understand the physical basis of TTF efficacy through retrospective analysis and to improve TTF treatment planning.
AI snapshot
Written from the paper’s full text.
TL;DR
Using an MRI-derived finite element head model with scalp transducer arrays mimicking the NovoTTF device, this study predicts the electric field distribution in the brain during tumor treating fields for glioblastoma. The field is highly non-uniform, mostly 0.5–2.0 V/cm, exceeds 1.0 V/cm in 60% of brain volume, and depends strongly on tissue geometry and conductivity.
Key findings
- At 200 kHz and 100 mA per active transducer, the calculated electric field in the brain varied mostly between 0.5 and 2.0 V/cm and exceeded 1.0 V/cm in 60% of total brain volume; 40% of the brain exceeded 1 V/cm in both left-right and anterior-posterior array configurations.
- Local field enhancement (“hotspots”) occurred near interfaces between tissues with different conductivities where the field was perpendicular to the interface; increases were strongest near the ventricles, and also appeared outside the tumor’s necrotic core and at some gray matter–white matter interfaces.
- In a virtual lesion model, the field was very low in the necrotic core, lower on average in the tumor shell than in contralateral white matter, but increased near the two “poles” and reduced around the “equator”; this directional effect was more pronounced in the left-right configuration.
- Average electric field under all transducer arrays was 5.1 V/cm in scalp and 31 V/cm in skull; corresponding SAR values were 81 W/kg and 77 W/kg, and average SAR in the brain cuboid regions defined by the array pairs was 1.6 W/kg.
Methods
- A realistic head model was created from MRI data and segmented into scalp, skull, cerebrospinal fluid, gray matter, and white matter. Two pairs of 3×3 transducer arrays were placed on the scalp: left-right temporal/parietal and anterior-posterior supraorbital/back-of-head. Transducers were ceramic disks 1 mm high and 9 mm radius, with center separations of 22 mm and 33 mm, and conductive gel 0.5–2 mm thick.
- A “virtual lesion” of two concentric spheres was placed in white matter near a lateral ventricle, representing a necrotic core surrounded by a 3 mm-thick active tumor shell; inner and outer diameters were 1.4 cm and 2.0 cm.
- The finite element method was used under the electro-quasistatic approximation to solve Laplace’s equation at 200 kHz, with 100 mA impressed current per active transducer (200 mA peak-to-peak). Tissues were assumed isotropic, with conductivity and relative permittivity values taken from the literature; calculations were performed for left-right active and anterior-posterior active configurations.
Limitations
- The paper states uncertainty in the electric properties used, which could affect calculated field values, and notes that white matter anisotropy was not included; future work is planned to incorporate DTI-derived anisotropic conductivity and to perform sensitivity analyses for conductivity and tissue thickness.
- The model uses an idealized virtual tumor and does not represent peritumoral edema, deformed ventricles, or real patient tumors; the paper states that patient-specific models could provide more accurate maps.
- The paper notes little information is available on tumor conductivity at around 200 kHz. Evident from the text: results come from a single realistic head model with literature-derived “typical” tissue values, so inter-subject anatomical and dielectric variability is not captured.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 17 cited sources checked · 0 supported · 0 flagged
- Findingown data
In the brain, the calculated electric field varied mostly between 0.5 and 2.0 V/cm.
“The calculated electric field in the brain varied mostly between 0.5 and 2.0 V/cm and exceeded 1.0 V/cm in 60% of the total brain volume.”
Quote in the paperSubstantial claim - Findingown data
The electric field distribution is highly non-uniform.
“The electric field distribution is highly non-uniform and depends on tissue geometry and dielectric properties.”
- Also stated in: § CONCLUSION · plain
“The distribution is highly nonuniform and depends on tissue geometry and dielectric properties, which could explain some of the variability in treatment outcomes.”
Quote in the paperSubstantial claim - Also stated in: § CONCLUSION · plain
- Findingown data
Regions of local field enhancement occurred near interfaces between tissues with different conductivities wherever the electric field was perpendicular to those interfaces.
“Regions of local field enhancement occurred near interfaces between tissues with different conductivities wherever the electric field was perpendicular to those interfaces.”
Quote in the paperSubstantial claim - Findingown data
The calculated electric field exceeded 1.0 V/cm in 60% of the total brain volume.
“The calculated electric field in the brain varied mostly between 0.5 and 2.0 V/cm and exceeded 1.0 V/cm in 60% of the total brain volume.”
Quote in the paperSubstantial claim - Findingown data
The electric field distribution depends on tissue geometry and dielectric properties.
“The electric field distribution is highly non-uniform and depends on tissue geometry and dielectric properties.”
- Also stated in: § CONCLUSION · plain
“The distribution is highly nonuniform and depends on tissue geometry and dielectric properties, which could explain some of the variability in treatment outcomes.”
Quote in the paperSubstantial claim - Also stated in: § CONCLUSION · plain
- Findingown data
The local field increases were strongest near the ventricles.
“These increases were strongest near the ventricles but were also present outside the tumor’s necrotic core and in some parts of the gray matter-white matter interface.”
Quote in the paperNot a substantial claim - Findingreasoning
As a result of tissue heterogeneity, the electric field in the brain does not decrease smoothly with distance from the transducers, as it would in a homogeneous tissue.
“As a result of tissue heterogeneity, the electric field in the brain does not decrease smoothly with distance from the transducers, as it would in a homogeneous tissue.”
Quote in the paperSubstantial claim - Findingnone given
The increase in the electric field in the WM is more evident closer to the arrays.
“The increase in the electric field in the WM is more evident closer to the arrays.”
Quote in the paperNot a substantial claim - Findingreasoning
The directional field effect is clearly visible in the vicinity of the lateral ventricles, where the high conductivity of the CSF leads to an increase in the electric field in the surrounding brain tissue.
“This directional effect is clearly visible in the vicinity of the lateral ventricles, where the high conductivity of the CSF leads to an increase in the electric field in the surrounding brain tissue.”
Quote in the paperNot a substantial claim - Findingown data
The average SAR in the part of the brain contained in the two cuboid regions defined by the AP and by the LR transducer array pairs was 1.6 W/kg.
“The average SAR in the part of the brain contained in the two cuboid regions defined by the AP and by the LR transducer array pairs was 1.6 W/kg.”
Quote in the paperNot a substantial claim - Findingown data
The effect of the virtual tumor on the local electric field distribution is more pronounced in the LR configuration due to the higher electric field it produces at the location of the tumor.
“The effect is more pronounced in the LR configuration due to the higher electric field it produces at the location of the tumor.”
Quote in the paperNot a substantial claim - Findingreasoning
In the virtual tumor, the field is very low in the necrotic core due to its high conductivity.
“The field is very low in the necrotic core due to its high conductivity.”
Quote in the paperNot a substantial claim - Findingnone given
The field intensity is lower in slices below and above the arrays.
“Nonetheless, the field intensity is lower in slices below and above the arrays.”
Quote in the paperNot a substantial claim - Findingown data
40% of the brain is exposed to an electric field greater than 1 V/cm in both array configurations.
“we also calculated that 40% of the brain is exposed to an electric field greater than 1 V/cm in both array configurations (AP*LR, Figure 3).”
Quote in the paperSubstantial claim - Findingown data
In the tumor shell, where the conductivity is twice that of WM, the average electric field is lower than in the corresponding region of the contralateral hemisphere.
“In the tumor shell, where the conductivity is twice that of WM, the average electric field is lower than in the corresponding region of the contralateral hemisphere.”
Quote in the paperNot a substantial claim - Findingreasoning
The field is slightly more uniform in the AP configuration than in the LR configuration.
“On the other hand, the field is slightly more uniform in the AP configuration, partly because the effect of the ventricles is less marked and partly because the arrays cover a larger part of the cross-section of the brain seen along the AP direction.”
Quote in the paperNot a substantial claim - Findingown data
In both LR and AP configurations, the magnitude of the electric field exceeded 1 V/cm over large areas of the brain.
“In both configurations, the magnitude of the electric field exceeded 1 V/cm over large areas of the brain.”
Quote in the paperSubstantial claim - Findingreasoning
The electric field exceeded 1 V/cm over a large part of the brain in the inferior-superior direction.
“The electric field also exceeded 1 V/cm over a large part of the brain in the inferior-superior direction, due to the large dimensions of the arrays (about 6.2 cm by 8.4 cm).”
Quote in the paperSubstantial claim - Findingnone given
The field is slightly higher in the LR than in the AP configuration in the regions close to the ventricles.
“The field is slightly higher in the LR than in the AP configuration, in the regions close to the ventricles.”
Quote in the paperNot a substantial claim - Findingnone given
The SAR values in the scalp and skull under the transducer arrays are high compared with the 3.2 W/kg limit set by International Standard IEC 60601-2-33 2010 for MR imaging of the head.
“The SAR values in the scalp and skull under the transducer arrays are high compared with the 3.2 W/kg limit set by International Standard IEC 60601-2-33 2010 for MR imaging of the head.”
Quote in the paperNot a substantial claim - Findingcitation
The electric field values reported in this study are similar to or greater than those calculated in transcranial magnetic stimulation (TMS) modeling studies, which are typically around 1 V/cm at threshold.
“Interestingly, the electric field values reported in this study are similar to or greater than those calculated in transcranial magnetic stimulation (TMS) modeling studies, which are typically around 1 V/cm at threshold (Roth et al., 1991, Salvador et al., 2011).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites Roth et al., 1991
Not checked in the free run.
- cites Salvador et al., 2011
Not checked in the free run.
- Interpretationreasoning
The non-uniform electric field distribution could explain some of the variability in treatment outcomes.
“This could explain some of the variability in treatment outcomes.”
- Also stated in: § CONCLUSION · hedged
“The distribution is highly nonuniform and depends on tissue geometry and dielectric properties, which could explain some of the variability in treatment outcomes.”
Quote in the paperSubstantial claim - Also stated in: § CONCLUSION · hedged
- Interpretationcitation
The electric field values predicted in this model brain are in reasonably good agreement with those that have been shown to reduce cancer cell proliferation in vitro.
“The electric field values predicted in this model brain are in reasonably good agreement with those that have been shown to reduce cancer cell proliferation in vitro.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Kirson et al., 2007
Not checked in the free run.
- Premisecitation
In vitro experiments showed that quiescent cells remained morphologically and functionally intact after TTF treatment.
“In vitro experiments also showed that quiescent cells remained morphologically and functionally intact after TTF treatment (Kirson et al., 2004).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Kirson et al., 2004
Not checked in the free run.
- Premisecitation
Applying electric fields with an optimal frequency of 200 kHz and amplitudes in the range of 1-3 V/cm disrupts the growth of GBM cells in culture.
“Specifically, it was reported that by applying electric fields with an optimal frequency of 200 kHz and amplitudes in the range of 1–3 V/cm, the growth of GBM cells in culture could be disrupted (Kirson et al., 2007).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Kirson et al., 2007
Not checked in the free run.
- Study design and conductcitation
The model geometry accurately represents the geometry of the arrays supplied with the NovoTTF system.
“This accurately represents the geometry of the arrays supplied with the NovoTTF system (http://www.novocure.com) (private communication, E. Kirson, Novocure, July 2012).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites private communication, E. Kirson, Novocure, July 2012
Not checked in the free run.
- Interpretationcitation
For a given tissue geometry, the intensity of the secondary electric field relative to that of the applied electric field depends only on the relative values of the conductivity, not the absolute values.
“Thus, for a given tissue geometry, the intensity of the secondary electric field relative to that of the applied electric field, i.e., the pattern of hotspots, depends only on the relative values of the conductivity, not the absolute values.”
Quote in the paperSubstantial claim - Premisenone given
Published data consistently shows that the conductivity of CSF is at least 4 to 6 times higher than that of GM and WM.
“Published data consistently shows that the conductivity of CSF is at least 4 to 6 time higher than that of GM and WM.”
Quote in the paperNot a substantial claim - Interpretationreasoning
The electric field in the tumor is not uniform even when the tumor is subject to a uniform applied electric field.
“As a result, the electric field in the tumor is not uniform even when the tumor is subject to a uniform applied electric field.”
Quote in the paperSubstantial claim - Interpretationcitation
For the parameters used in this model, the current in the head is mainly resistive (σ ≫ ωεrε0).
“However, for the parameters used in this model the current in the head is mainly resistive, i.e., σ ≫ ωεrε0, where ω is the angular frequency, and ε0 is the permittivity of vacuum (Plonsey and Heppner, 1967).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Plonsey and Heppner, 1967
Not checked in the free run.
- Interpretationown data
It is possible that the electric field value required to achieve complete proliferation arrest in glioma cells following a 24 h exposure to TTFields, 2.25 V/cm, may only be achieved in limited and specific regions of the brain.
“On the other hand, it is possible that the electric field value required to achieve complete proliferation arrest in glioma cells following a 24 h exposure to TTFields, 2.25 V/cm (Kirson et al., 2004), may only be achieved in limited and specific regions of the brain.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Kirson et al., 2004
Not checked in the free run.
- Interpretationcitation
The existence of electric field hotspots is due to a secondary electric field generated by charge accumulation at tissue interfaces.
“The existence of electric field hotspots is due to a secondary electric field generated by charge accumulation at tissue interfaces.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Miranda et al., 2007 source
Not checked in the free run.
- Interpretationreasoning
The prediction of the existence of hotspots at WM-CSF and GM-CSF interfaces is robust.
“Thus the prediction of the existence of hotspots at WM-CSF and GM-CSF interfaces is a robust one.”
Quote in the paperSubstantial claim - Premisecitation
In the completed clinical trial, the largest dimension of the tumor treated with TTFs had a median of 6.1 cm and a range of 0-15.2 cm.
“In the completed clinical trial, the largest dimension of the tumor treated with TTFs had a median of 6.1 cm and a range of 0–15.2 cm (Stupp et al., 2012).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Stupp et al., 2012
Not checked in the free run.
- Premisecitation
A medical device using the TTF mechanism was approved by the FDA for use in patients with recurrent GBM following a Phase III trial.
“A medical device using this mechanism of action was approved by the US Food and Drug Administration (FDA) for use in patients with recurrent GBM, following the completion of a Phase III trial (Stupp et al., 2012).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Stupp et al., 2012
Not checked in the free run.
- Interpretationreasoning
Tissue heterogeneity is expected to affect the electric field distribution in the tumor region.
“Tissue heterogeneity is also expected to affect the electric field distribution in the tumor region.”
Quote in the paperSubstantial claim - Interpretationreasoning
It is likely that an electric field oscillating at 200 kHz with an amplitude of 1 V/cm is unable to depolarize a neuron to the point of generating an action potential.
“It is therefore likely that an electric field oscillating at 200 kHz with an amplitude of 1 V/cm is unable to depolarize a neuron to the point of generating an action potential.”
Quote in the paperSubstantial claim - Interpretationnone given
We predicted for the first time the electric field distribution in the brain during the application of tumor treating fields using a computational modeling framework.
“We predicted for the first time the electric field distribution in the brain during the application of tumor treating fields using a computational modeling framework.”
Quote in the paperSubstantial claim - Premisecitation
Effects on the scalp seem to be limited to the mild to moderate contact dermatitis that was observed beneath the transducer arrays in 16% of TTF patients in the clinical trial.
“Despite these high values, effects on the scalp seem to be limited to the mild to moderate contact dermatitis that was observed beneath the transducer arrays in 16% of TTF patients in the clinical trial (Stupp et al., 2012).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Stupp et al., 2012
Not checked in the free run.
- Interpretationcitation
The limited scalp effect may be due to the power delivered by the TTF device being lowered automatically when the temperature of any transducer exceeded 41°C.
“This limited effect may be due to the power delivered by the TTF device being lowered automatically when the temperature of any transducer exceeded 41°C (Kirson et al., 2007).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites Kirson et al., 2007
Not checked in the free run.
- Interpretationreasoning
The answer to why TTFs do not stimulate neurons in the same way as TMS lies mainly in the different frequencies employed: 3 kHz for biphasic TMS pulses and 200 kHz for TTFs.
“The answer lies mainly in the different frequencies employed in the two techniques: 3 kHz for biphasic TMS pulses and 200 kHz for TTFs.”
Quote in the paperSubstantial claim
- May combine two claims. 16
- Classified as probably not a substantial claim. 6
May combine two claims.
Findingown dataThe local field increases were also present outside the tumor's necrotic core and in some parts of the gray matter-white matter interface.
“These increases were strongest near the ventricles but were also present outside the tumor’s necrotic core and in some parts of the gray matter-white matter interface.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingnone givenNear interfaces that are perpendicular to the applied electric field, the field is increased in the low conductivity tissue and decreased in the high conductivity region.
“Also, near interfaces that are perpendicular to the applied electric field, the field is increased in the low conductivity tissue and decreased in the high conductivity region.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe average electric field values under all transducer arrays were 5.1 V/cm in the scalp and 31 V/cm in the skull.
“The average electric field values under all transducer arrays were 5.1 V/cm in the scalp and 31 V/cm in the skull, respectively.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningElectric field hotspots can occur far from the arrays, giving rise to a complex spatial distribution.
“Also, electric field hotspots can occur far from the arrays, giving rise to a complex spatial distribution (Figure 2).”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataIn the tumor shell, the field is far from uniform: it is increased in the vicinity of the two poles where the applied electric field is perpendicular to the spherical surface, and it is reduced around the equator.
“However, directional effects come into play here, too, and the field in the shell is far from uniform: in both configurations, it is increased in the vicinity of the two “poles” where the applied electric field is perpendicular to the spherical surface, and it is reduced around the “equator”.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe corresponding SAR values were 81 W/kg in the scalp and 77 W/kg in the skull.
“The corresponding SAR values were 81 W/kg and 77 W/kg.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningThe magnitude of the electric field is lower in GM than in WM because GM conductivity is higher than that of WM.
“For example, the magnitude of the electric field is lower in GM than in WM because its conductivity is higher than that of WM.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningThe directional field effect is also present at WM-GM interfaces with the appropriate orientation relative to the applied electric field, but is smaller because the ratio of the conductivities of the two tissues is closer to 1.
“It is also present at WM-GM interfaces with the appropriate orientation relative to the applied electric field. In this case, the effect is smaller because the ratio of the conductivities of the two tissues is closer to 1.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Premisenone givenWM is anisotropic as its conductivity depends on fiber orientation.
“However, WM is anisotropic as its conductivity depends on fiber orientation.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenThere is some uncertainty in the electric properties used in this study, which could affect the calculated electric field values.
“It should be noted that there is some uncertainty in the electric properties used in this study, which could affect the calculated electric field values.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe electromagnetic wavelength in the different tissue types is much larger than the size of the head, so the electro-quasistatic approximation of Maxwell's equations applies.
“The electromagnetic wavelength in the different tissue types is much larger than the size of the head (15–150 m vs 0.2 m) and so the electro-quasistatic approximation of Maxwell’s equations applies (Haus and Melcher, 1989).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Haus and Melcher, 1989
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenThe mean conductivity of WM is lower than that of GM by a factor of about 2.
“It is also generally accepted that the mean conductivity of WM is lower than that of GM, by a factor of about 2.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationFor purely resistive tissues, the secondary field depends only on the ratio of the conductivities of the two adjacent tissues, and is proportional to the strength of the normal component of the applied electric field.
“For purely resistive tissues, the secondary field depends only on the ratio of the conductivities of the two adjacent tissues, and is proportional to the strength of the normal component of the applied electric field (Miranda et al., 2007).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Miranda et al., 2007 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenNo significant temperature increase is expected in the brain due to heat dissipation in the tissue.
“No significant temperature increase is expected in the brain due to heat dissipation in the tissue.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningTumors close to the ventricles may be exposed to higher electric fields, as will superficial tumors close to a transducer.
“For example, tumors close to the ventricles may be exposed to higher electric fields, as will superficial tumors close to a transducer.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningThe non-uniformity of the electric field could lead to different treatment outcomes depending on the position of the tumor relative to different tissue interfaces, and to the transducers.
“This non-uniformity of the electric field could lead to different treatment outcomes depending on the position of the tumor relative to different tissue interfaces, and to the transducers.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningTTF could potentially target GBM cells selectively while leaving normal brain cells relatively unaffected because GBM cells divide rapidly while other brain cells divide infrequently.
“Because GBM cells divide rapidly while other brain cells divide infrequently, the rationale of using TTFs is that they could potentially target GBM cells selectively while leaving normal brain cells relatively unaffected.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenThe presence of a tumor, peritumoral edema, and, in some cases, deformed ventricles, is expected to alter the electric field distribution substantially.
“However, the presence of a tumor, peritumoral edema, and, in some cases, deformed ventricles, is expected to alter this distribution substantially.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable).
Interpretationown dataThe figures presented in this study and the considerations outlined in this section give a reasonable characterization of the electric field distribution in the brain during a TTF treatment.
“The figures presented in this study and the considerations outlined in this section give a reasonable characterization of the electric field distribution in the brain during a TTF treatment.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningBecause the electric field in the brain is not uniform, tumor size will influence the effective electric field over the whole tumor and therefore represents another potential source of variability of the treatment outcome.
“Because the electric field in the brain is not uniform, tumor size will influence the effective electric field over the whole tumor and therefore represents another potential source of variability of the treatment outcome, in addition to tumor location and to heterogeneity effects.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationcitationThe effect of an alternating electric field on membrane polarization is expected to diminish for frequencies greater than 10 kHz, given that the neural membrane time constant is about 100 μs or greater.
“Since the neural membrane time constant is about 100 μs (Barker et al., 1991) or greater, the effect of an alternating electric field on membrane polarization is expected to diminish for frequencies greater than 10 kHz.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Barker et al., 1991
Not checked in the free run.
May combine two claims.
PremisereasoningHaematological adverse effects greater than grade 2 only affected 3% of TTF patients in the clinical trial, probably because the marrow in other bones was unaffected.
“Nonetheless, haematological adverse effects greater than grade 2 only affected 3% of TTF patients in the clinical trial (Stupp et al., 2012), probably because the marrow in other bones was unaffected.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites Stupp et al., 2012
Not checked in the free run.
The authors state this as an assumption.
The tissues in the head model are isotropic.
“The tissues were assumed to be isotropic and the values for the electrical conductivity (σ) and relative permittivity (εr) at 200 kHz were estimated from the literature:”
The paper relies on this without support.
No physics-based models exist to predict the electric field and current distributions in the scalp, skull, cerebrospinal fluid, and brain parenchyma produced by a TTF-generating medical device.
“To date, however, there have been no physics-based models to predict the electric field and current distributions in the scalp, skull, cerebrospinal fluid, and brain parenchyma produced by a TTF-generating medical device.”
The paper relies on this without support.
The core and edematous regions of glioblastoma have higher conductivities than normal tissue, whereas the high cellularity region has a lower conductivity.
“The core and the edematous regions are likely to have higher conductivities than normal tissue whereas the high cellularity region may have a lower conductivity.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Different field strengths in a virtual lesion that represents a tumour were predicted for the LR and AP array pairs.
“Furthermore, different field strengths in a virtual lesion that represents a tumour were predicted for the LR and AP array pairs (Miranda et al 2014, Wenger et al 2013, 2014a).”
From The electric field distribution in the brain during TTFields therapy and its dependence on tissue dielectric properties and anatomy: a computational study (2015) · cites this paper as Miranda et al 2014
The induced field was calculated to be higher than 1 V/cm in over 60% of the brain.
“The induced field was calculated to be higher than 1 V/cm in over 60% of the brain.”
From The electric field distribution in the brain during TTFields therapy and its dependence on tissue dielectric properties and anatomy: a computational study (2015) · cites this paper as Miranda et al 2014
In s1 the average SAR in the scalp and skull directly underneath the transducer arrays were 81 W/kg and 77 W/kg respectively.
“In s1 the average SAR in the scalp and skull directly underneath the transducer arrays were already calculated to be 81 W/kg and 77 W/kg respectively (Miranda et al 2014).”
From The electric field distribution in the brain during TTFields therapy and its dependence on tissue dielectric properties and anatomy: a computational study (2015) · cites this paper as Miranda et al 2014
Only limited adverse effects were reported in TTFields patients.
“only limited adverse effects were reported in TTFields patients as discussed in more detail in a previous paper (Miranda et al 2014).”
From The electric field distribution in the brain during TTFields therapy and its dependence on tissue dielectric properties and anatomy: a computational study (2015) · cites this paper as Miranda et al 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Either-configuration label uses an undefined LP configuration
MinorThe paper defines the two array configurations as LR and AP, but labels the volume exposed in either configuration as "LR+LP." The label is inconsistent with the stated configurations.
“The graph in the bottom right shows the percentage of the volume of the brain where the electric field exceeded a certain value in both configurations (LR*AP) or in either configuration (LR+LP).”
“The electric field calculations were performed for two different transducer array configurations: LR arrays active and AP arrays inactive (LR configuration), and AP arrays active and LR arrays inactive (AP configuration).”
Cites
Radiotherapy Plus Concomitant and Adjuvant Temozolomide for Glioblastoma
Stupp, R., Mason, W. P., van den Bent, M. J., Weller, M., Fisher, B., Taphoorn, M. J. B., Belanger, K., Brandes, A. A., Marosi, C., Bogdahn, U., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043330 · Cited by 21,807 · see citing works
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · see citing works
Self-citationGabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · see citing works
Alternating electric fields arrest cell proliferation in animal tumor models and human brain tumors
Kirson, E. D., Dbalý, V., Tovaryš, F., Vymazal, J., Soustiel, J. F., Itzhaki, A., Mordechovich, D., Steinberg-Shapira, S., Gurvich, Z., Schneiderman, R., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702916104 · Cited by 894 · see citing works
Stupp, R., Wong, E. T., Kanner, A. A., Steinberg, D., Engelhard, H., Heidecke, V., Kirson, E. D., Taillibert, S., Liebermann, F., Dbalý, V., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2012.04.011 · Cited by 862 · see citing works
Disruption of cancer cell replication by alternating electric fields
Kirson, E. D., Gurvich, Z., Schneiderman, R., Dekel, E., Itzhaki, A., Wasserman, Y., Schatzberger, R., & Palti, Y. (2004) · Cancer research · doi:10.1158/0008-5472.can-04-0083 · Cited by 827 · see citing works
Electromagnetic fields and energy
Haus, H. A., & Melcher, J. R. (1989) · BiblioBoard Library Catalog (Open Research Library) · Cited by 775 · see citing works
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M. P., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762 · see citing works
Self-citationDielectric properties of breast carcinoma and the surrounding tissues
Surowiec, A., Stuchly, S. S., Barr, J. R., et al. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1374 · Cited by 736 · see citing works
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 718 · see citing works
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · Bulletin of Mathematical Biology · doi:10.1007/bf02476917 · Cited by 623 · see citing works
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 592 · see citing works
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494 · see citing works
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D. M., Koch, M., & MacLeod, R. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452 · see citing works
In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 447 · see citing works
Electrical properties of the epidermal stratum corneum
Yamamoto, T., & Yamamoto, Y. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478741 · Cited by 438 · see citing works
Conductivity tensor mapping of the human brain using diffusion tensor MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J., & Belliveau, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171473898 · Cited by 436 · see citing works
Ruffini, G., Fox, M., Ripollés, O., Miranda, P. C., & Pascual‐Leone, Á. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.002 · Cited by 352 · see citing works
Self-citationThe electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 333 · see citing works
Self-citationA theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307 · see citing works
Specific impedance of rabbit cerebral cortex
Ranck, J. B. (1963) · Experimental Neurology · doi:10.1016/s0014-4886(63)80005-9 · Cited by 256 · see citing works
Dielectric properties of mammalian tissues from 0.1 to 100 MHz; a summary of recent data
Stoy, R. D., Foster, K. R., & Schwan, H. P. (1982) · Physics in Medicine and Biology · doi:10.1088/0031-9155/27/4/002 · Cited by 248 · see citing works
Kirson, E. D., Schneiderman, R. S., Dbalý, V., Tovaryš, F., Vymazal, J., Itzhaki, A., Mordechovich, D., Gurvich, Z., Shmueli, E., Goldsher, D., et al. (2009) · BMC Medical Physics · doi:10.1186/1756-6649-9-1 · Cited by 224 · see citing works
Güllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 211 · see citing works
Thickness and resistivity variations over the upper surface of the human skull
Law, S. K. (1993) · Brain Topography · doi:10.1007/bf01191074 · Cited by 208 · see citing works
Alternating electric fields (TTFields) inhibit metastatic spread of solid tumors to the lungs
Kirson, E. D., Giladi, M., Gurvich, Z., Itzhaki, A., Mordechovich, D., Schneiderman, R. S., Wasserman, Y., Ryffel, B., Goldsher, D., & Palti, Y. (2009) · Clinical & Experimental Metastasis · doi:10.1007/s10585-009-9262-y · Cited by 171 · see citing works
Salvador, R., Silva, S., Basser, P. J., & Miranda, P. C. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.09.022 · Cited by 168 · see citing works
Self-citationSome relations between resistivity and electrical activity in the cerebral cortex of the cat
W. H., F. J., & Landau, W. M. (1955) · Journal of Cellular and Comparative Physiology · doi:10.1002/jcp.1030450305 · Cited by 166 · see citing works
Conductivity of living intracranial tissues
Latikka, J., Kuurne, T., & Eskola, H. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/6/302 · Cited by 161 · see citing works
Dielectric Permittivity and Electrical Conductivity of Fluid Saturated Bone
Kosterich, J. D., Foster, K. R., & Pollack, S. R. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325201 · Cited by 160 · see citing works
Barker, A. T., Garnham, C., & Freeston, I. L. (1991) · PubMed · Cited by 150 · see citing works
Physiological measurements using ultra-high field fMRI: a review
Francis, S., & Sánchez-Panchuelo, R.-M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/r167 · Cited by 141 · see citing works
Measurements of the specific Resistance of the human Body to direct Current
Bürger, H., & Milaan, J. B. V. (1943) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1943.tb11253.x · Cited by 122 · see citing works
THE ELECTRICAL CONDUCTIVITY OF ANIMAL TISSUES UNDER NORMAL AND PATHOLOGICAL CONDITIONS
Crile, G. W., Hosmer, H. R., & Rowland, A. F. (1922) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1922.60.1.59 · Cited by 104 · see citing works
Tissue heterogeneity as a mechanism for localized neural stimulation by applied electric fields
Miranda, P. C., Correia, L., Salvador, R., & Basser, P. J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/009 · Cited by 83 · see citing works
Self-citationMerlet, I., Birot, G., Salvador, R., Molaee-Ardekani, B., Mekonnen, A., Soria‐Frisch, A., Ruffini, G., Miranda, P. C., & Wendling, F. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057330 · Cited by 81 · see citing works
Self-citationElectrical and Dielectric Properties of Wet Bone as a Function of Frequency
Reddy, G. N., & Saha, S. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325268 · Cited by 80 · see citing works
Status Quo—Standard-of-Care Medical and Radiation Therapy for Glioblastoma
Becker, K. P., & Yu, J. B. (2012) · The Cancer Journal · doi:10.1097/ppo.0b013e318244d7eb · Cited by 72 · see citing works
Specific impedance of rabbit's cortical tissue
Harreveld, A. V., Murphy, T. M., & Nobel, K. W. (1963) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1963.205.1.203 · Cited by 68 · see citing works
Hallez, H., Vanrumste, B., Hese, P. V., Delputte, S., & Lemahieu, I. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/7/005 · Cited by 66 · see citing works
Dielectric properties of human glioma and surrounding tissue
Lu, Y., Li, B., Xu, J., et al. (1992) · International Journal of Hyperthermia · doi:10.3109/02656739209005023 · Cited by 62 · see citing works
Dielectric Properties of Solid Tumors During Nonnothermia and Hyperthermia
Peloso, R. A., Tuma, D. T., & Jain, R. K. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325399 · Cited by 38 · see citing works
Postmortem changes of the dielectric properties of bovine brain tissues at low radiofrequencies
Surowiec, A., Stuchly, S. S., & Swarup, A. (1986) · Bioelectromagnetics · doi:10.1002/bem.2250070105 · Cited by 34 · see citing works
Mercato, G. D., & García-Sánchez, F. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.135546 · Cited by 29 · see citing works
THE HIGH FREQUENCY RESISTANCE OF HUMAN TISSUE
Hemingway, A., & McClendon, J. F. (1932) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1932.102.1.56 · Cited by 25 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Barker A T, 1991, Electroencephalogr. Clin. Neurophysiol. Suppl., 43, 227
- Miranda P C, 2013, ISMRM
Cited by
Sorted by citations
Tumor-Treating Fields: A Fourth Modality in Cancer Treatment
Mun, E. J., Babiker, H. M., Weinberg, U., Kirson, E. D., & Von Hoff, D. D. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-17-1117 · Cited by 380 · see citing works
Giladi, M., Schneiderman, R. S., Voloshin, T., Porat, Y., Munster, M., Blat, R., Sherbo, S., Bomzon, Z., Urman, N., Itzhaki, A., et al. (2015) · Scientific Reports · doi:10.1038/srep18046 · Cited by 327 · see citing works
Wenger, C., Salvador, R., Basser, P. J., & Miranda, P. C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/18/7339 · Cited by 121 · see citing works
Self-citationAn Evidence-Based Review of Alternating Electric Fields Therapy for Malignant Gliomas
Wong, E. T., Lok, E., & Swanson, K. D. (2015) · Current Treatment Options in Oncology · doi:10.1007/s11864-015-0353-5 · Cited by 35 · see citing works
Porat, Y., Giladi, M., Schneiderman, R. S., Blat, R., Shteingauz, A., Zeevi, E., Munster, M., Voloshin, T., Kaynan, N., Tal, O., et al. (2017) · Journal of Visualized Experiments · doi:10.3791/55820-v · Cited by 25 · see citing works
Singh, P., Ray, K., Fujita, D., & Bandyopadhyay, A. (2019) · Lecture Notes in Electrical Engineering · doi:10.1007/978-981-13-1642-5_63 · Cited by 20 · see citing works
The electrical conductivity of human cerebrospinal fluid in vivo
Latikka, J., & Eskola, H. (2019) · IFMBE Proceedings · doi:10.1007/978-981-10-9035-6_142 · Cited by 15 · see citing works
- Authors
- Miranda, P. C., Mekonnen, A., Salvador, R., & Basser, P. J.
- Affiliations
- University of Lisbon (PT)
- National Institutes of Health (US)
- Corresponding author
- Miranda, Pedro C
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-07-08
- Volume
- 59
- Issue
- 15
- Pages
- 4137-4147
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- PMC
- PMC4137229
- OpenAlex
- W2136891515
- Semantic Scholar
- d97c816ffda973fc60548ce0f614f31d48a45fd8
- Cited by
- 131
- References
- 45
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 12 · 2023: 9 · 2022: 12 · 2021: 15 · 2020: 10 · 2019: 12 · 2018: 10 · 2017: 10 · 2016: 16 · 2015: 11
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- European Commission (222079)
- Ministry of Science and Technology, Croatia
- National Institutes of Health
- Fundação para a Ciência e a Tecnologia
- National Institute of Child Health and Human Development
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (ZIAHD000268)
- Topics
- Health Sciences › Medicine › Genetics › Glioma Diagnosis and Treatment
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Keywords
- tumor treating fields, glioblastoma, electric field distribution, finite element analysis, realistic head model, tissue dielectric properties, transducer array, virtual lesion, treatment planning, recurrent glioblastoma
- MeSH terms
- Brain, Electricity, Glioblastoma, Humans, Models, Neurological, Brain Waves, Transcranial Direct Current Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-10.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-10.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review