CoChat

Comparison of oxygen uptake kinetics during knee extension and cycle exercise

Koga, Shunsaku, Poole, David C., Shiojiri, Tomoyuki, Kondo, Narihiko, Fukuba, Yoshiyuki, Miura, Akira, Barstow, Thomas J. · 2005 · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Cited by 130

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The knee extension exercise (KE) model engenders different muscle and fiber recruitment patterns, blood flow, and energetic responses compared with conventional cycle ergometry (CE). This investigation had two aims: 1) to test the hypothesis that upright two-leg KE and CE in the same subjects would yield fundamentally different pulmonary O 2 uptake (pV̇o 2) kinetics and 2) to characterize the muscle blood flow, muscle V̇o 2 (mV̇o 2), and pV̇o 2 kinetics during KE to investigate the rate-limiting factor(s) of pV̇o 2 on kinetics and muscle energetics and their mechanistic bases after the onset of heavy exercise. Six subjects performed KE and CE transitions from unloaded to moderate [< ventilatory threshold (VT)] and heavy (>VT) exercise. In addition to pV̇o 2 during CE and KE, simultaneous pulsed and echo Doppler methods, combined with blood sampling from the femoral vein, were used to quantify the precise temporal profiles of femoral artery blood flow (LBF) and mV̇o 2 at the onset of KE. First, the gain (amplitude/work rate) of the primary component of pV̇o 2 for both moderate and heavy exercise was higher during KE (∼12 ml·W−1·min−1) compared with CE (∼10), but the time constants for the primary component did not differ. Furthermore, the mean response time (MRT) and the contribution of the slow component to the overall response for heavy KE were significantly greater than for CE. Second, the time constant for the primary component of mV̇o 2 during heavy KE [25.8 ± 9.0 s (SD)] was not significantly different from that of the phase II pV̇o 2. Moreover, the slow component of pV̇o 2 evident for the heavy KE reflected the gradual increase in mV̇o 2. The initial LBF kinetics after onset of KE were significantly faster than the phase II pV̇o 2 kinetics (moderate: time constant LBF = 8.0 ± 3.5 s, pV̇o 2 = 32.7 ± 5.6 s, P < 0.05; heavy: LBF = 9.7 ± 2.0 s, pV̇o 2 = 29.9 ± 7.9 s, P < 0.05). The MRT of LBF was also significantly faster than that of pV̇o 2. These data demonstrate that the energetics (as gain) for KE are greater than for CE, but the kinetics of adjustment (as time constant for the primary component) are similar. Furthermore, the kinetics of muscle blood flow during KE are faster than those of pV̇o 2, consistent with an intramuscular limitation to V̇o 2 kinetics, i.e., a microvascular O 2 delivery-to-O 2 requirement mismatch or oxidative enzyme inertia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpregu.00147.2004

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Koga, S., Poole, D. C., Shiojiri, T., Kondo, N., Fukuba, Y., Miura, A., & Barstow, T. J.
Venue
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
2005-01
Volume
288
Issue
1
Pages
R212-R220
ISSN
  • 0363-6119 (ISSN-L)
  • 1522-1490
OpenAlex
W2156514897
Cited by
130
References
3
FWCI
15.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.