Reactive hyperemia: a review of methods, mechanisms, and considerations
The DOI matches its Crossref record; 109 of the 109 references it cites were found in a registry or an index.
Abstract
Reactive hyperemia is a well-established technique for noninvasive assessment of peripheral microvascular function and a predictor of all-cause and cardiovascular morbidity and mortality. In its simplest form, reactive hyperemia represents the magnitude of limb reperfusion following a brief period of ischemia induced by arterial occlusion. Over the past two decades, investigators have employed a variety of methods, including brachial artery velocity by Doppler ultrasound, tissue reperfusion by near-infrared spectroscopy, limb distension by venous occlusion plethysmography, and peripheral artery tonometry, to measure reactive hyperemia. Regardless of the technique used to measure reactive hyperemia, blunted reactive hyperemia is believed to reflect impaired microvascular function. With the advent of several technological advancements, together with an increased interest in the microcirculation, reactive hyperemia is becoming more common as a research tool and is widely used across multiple disciplines. With this in mind, we sought to review the various methodologies commonly used to assess reactive hyperemia and current mechanistic pathways believed to contribute to reactive hyperemia and reflect on several methodological considerations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corretti, M. C., Anderson, T. J., Benjamin, E. J., Celermajer, D., Charbonneau, F., Creager, M. A., Deanfield, J., Drexler, H., Gerhard-Herman, M., Herrington, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01746-6 · Cited by 4,604
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
K+ is an endothelium-derived hyperpolarizing factor in rat arteries
Edwards, G., Dora, K. A., Gardener, M. J., Garland, C. J., & Weston, A. H. (1998) · Nature · doi:10.1038/24388 · Cited by 1,058
Bonetti, P. O., Pumper, G. M., Higano, S. T., Holmes, D. R., Kuvin, J. T., & Lerman, A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.062 · Cited by 973
Ion Channels and Their Functional Role in Vascular Endothelium
Nilius, B., & Droogmans, G. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1415 · Cited by 868
ATP-sensitive and inwardly rectifying potassium channels in smooth muscle
Quayle, J. M., Nelson, M. T., & Standen, N. B. (1997) · Physiological Reviews · doi:10.1152/physrev.1997.77.4.1165 · Cited by 833
Self-citationVascular nitric oxide: Beyond eNOS
Zhao, Y., Vanhoutte, P. M., & Leung, S. W. S. (2015) · Journal of Pharmacological Sciences · doi:10.1016/j.jphs.2015.09.002 · Cited by 826
The Endothelium and Its Role in Regulating Vascular Tone
Sandoo, A., Veldhuijzen van Zanten, J. J. C. S., Metsios, G. S., Carroll, D., & Kitas, G. D. (2010) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192401004010302 · Cited by 814
Assessment of peripheral vascular endothelial function with finger arterial pulse wave amplitude
Kuvin, J. T., Patel, A. R., Sliney, K. A., Pandian, N. G., Sheffy, J., Schnall, R. P., Karas, R. H., & Udelson, J. E. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00094-2 · Cited by 773
Hamburg, N. M., Keyes, M. J., Larson, M. G., Vasan, R. S., Schnabel, R., Pryde, M. M., Mitchell, G. F., Sheffy, J., Vita, J. A., & Benjamin, E. J. (2008) · Circulation · doi:10.1161/circulationaha.107.748574 · Cited by 692
Cited by
Keller, J. L., Traylor, M. K., Gray, S. M., Hill, E. C., & Weir, J. P. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00174.2023 · Cited by 44
Cardiovascular risks and endothelial dysfunction in reproductive-age women with endometriosis
Smyk, J. M., Danielecka, Z., Kotowska, M., Zawadka, M., Andruszkiewicz, P., Grąt, M., Główczyńska, R., Grabowski, M., Gąsecka, A., & Romejko-Wolniewicz, E. (2024) · Scientific Reports · doi:10.1038/s41598-024-73841-7 · Cited by 22
Impact of cutaneous blood flow on NIR-DCS measures of skeletal muscle blood flow index
Bartlett, M. F., Akins, J. D., Oneglia, A. P., Brothers, R. M., Wilkes, D., & Nelson, M. D. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00337.2021 · Cited by 9
Self-citation
Metadata
- Authors
- Rosenberry, R., & Nelson, M. D.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2020-03-01
- Volume
- 318
- Issue
- 3
- Pages
- R605-R618
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W3005147803
- Cited by
- 242
- References
- 109
- FWCI
- 26.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.