Short-term and long-term blood pressure and heart rate variability in the mouse
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Knowledge on murine blood pressure and heart rate control mechanisms is limited. With the use of a tethering system, mean arterial pressure (MAP) and pulse interval (PI) were continuously recorded for periods up to 3 wk in Swiss mice. The day-to-day variation of MAP and PI was stable from 5 days after surgery. Within each mouse ( n = 9), MAP and PI varied by 21 ± 6 mmHg and 17 ± 4 ms around their respective 24-h averages (97 ± 3 mmHg and 89 ± 3 ms). Over 24-h periods, MAP and PI were bimodally distributed and clustered around two preferential states. Short-term variability of MAP and PI was compared between the resting (control) and active states using spectral analysis. In resting conditions, variability of MAP was mainly confined to frequencies <1 Hz, whereas variability of PI was predominantly linked to the respiration cycle (3–6 Hz). In the active state, MAP power increased in the 0.08- to 3-Hz range, whereas PI power fell in the 0.08- to 0.4-Hz range. In both conditions, coherence between MAP and PI was high at 0.4 Hz with MAP leading the PI fluctuations by 0.3–0.4 s, suggesting that reflex coupling between MAP and PI occurred at the same frequency range as in rats. Short-term variability of MAP and PI was studied after intravenous injection of autonomic blockers. Compared with the resting control state, MAP fell and PI increased after ganglionic blockade with hexamethonium. Comparable responses of MAP were obtained with the α-blocker prazosin, whereas the β-blocker metoprolol increased PI similarly. Muscarinic blockade with atropine did not significantly alter steady-state levels of MAP and PI. Both hexamethonium and prazosin decreased MAP variability in the 0.08- to 1-Hz range. In contrast, after hexamethonium and metoprolol, PI variability increased in the 0.4- to 3-Hz range. Atropine had no effect on MAP fluctuations but decreased those of PI in the 0.08- to 1-Hz range. These data indicate that, in mice, blood pressure and its variability are predominantly under sympathetic control, whereas both vagal and sympathetic nerves control PI variability. Blockade of endogenous nitric oxide formation by N G-nitro-l-arginine methyl ester increased MAP variability specifically in the 0.08- to 0.4-Hz range, suggesting a role of nitric oxide in buffering blood pressure fluctuations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertram, D., Barrès, C., Cuisinaud, G., & Julien, C. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.251by.x · Cited by 90
Cited by
Provenzano, P. P., Cuevas, C., Chang, A. E., Goel, V. K., Von Hoff, D. D., & Hingorani, S. R. (2012) · Cancer Cell · doi:10.1016/j.ccr.2012.01.007 · Cited by 2,195
“Tumor IFPs ranged from 75 to 130 mm Hg (mean = 99 mm Hg, n = 7, in KPC PDA; mean = 87 mm Hg, n = 4, in KC tumors), which vastly exceeded typical arteriolar and capillary pressures of 40–80 mm Hg and 15–40 mm Hg, respectively (Sherwood, 1997) and rivaled mean arterial pressure (Janssen et al., 2000; Mattson, 1998).”
BackgroundCardiac electrophysiology in mice: a matter of size
Kaese, S., & Verheule, S. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00345 · Cited by 196
“…activity, but in contrast to humans, mice already show a predominant sympathetic tone, since parasympathetic blockade does not increase in HR (Mansier et al., 1996; Wickman et al., 1998) but sympathetic blockade caused a pronounced decrease in HR (Janssen et al., 2000; Just et al., 2000).”
BackgroundMulder, M., Jansen, P. J., Janssen, B. J. A., van de Berg, W. D. J., van der Boom, H., Havekes, L. M., de Kloet, R. E., Ramaekers, F. C. S., & Blokland, A. (2004) · Neurobiology of Disease · doi:10.1016/j.nbd.2004.01.015 · Cited by 98
“Mice were instrumented with catheters as described in detail previously (Janssen et al., 2000).”
MethodSelf-citationNunn, N., Feetham, C. H., Martin, J., Barrett‐Jolley, R., & Plagge, A. (2013) · Experimental Physiology · doi:10.1113/expphysiol.2013.073064 · Cited by 17
“The cause of the elevated HR in Gnasxl KO mice was investigated by injection of reserpine and atropine to inhibit sympathetic and parasympathetic stimulation, respectively, of the cardiovascular system (Janssen et al. 2000; Young & Davisson, 2011).”
BackgroundMethodInfluential
Metadata
- Authors
- Janssen, B. J. A., Leenders, P. J. A., & Smits, J. F. M.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2000-01-01
- Volume
- 278
- Issue
- 1
- Pages
- R215-R225
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2157426516
- Cited by
- 132
- References
- 1
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.