Intravital multiphoton microscopy of dynamic renal processes
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Recent advances in microscopy and optics, computer sciences, and the available fluorophores used to label molecules of interest have empowered investigators to utilize intravital two-photon microscopy to study the dynamic events within the functioning kidney. This emerging technique enables investigators to follow functional and structural alterations with subcellular resolution within the same field of view over seconds to weeks. This approach invigorates the validity of data and facilitates analysis and interpretation as trends are more readily determined when one is more closely monitoring indicative physiological parameters. Therefore, in this review we emphasize how specific approaches will enable studies into glomerular permeability, proximal tubule endocytosis, and microvascular function within the kidney. We attempt to show how visual data can be quantified, thus allowing enhanced understanding of the process under study. Finally, emphasis is given to the possible future opportunities of this technology and its present limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893 · cited 3×
“NEW IMAGING TECHNOLOGIES, such as multiphoton microscopy, have equipped researchers with extremely powerful tools to uniquely address biologically important questions that can only be accomplished in whole organ studies (1, 11, 16).”
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179 · cited 1×
“NEW IMAGING TECHNOLOGIES, such as multiphoton microscopy, have equipped researchers with extremely powerful tools to uniquely address biologically important questions that can only be accomplished in whole organ studies (1, 11, 16).”
Photobleaching and photoactivation: following protein dynamics in living cells.
Lippincott‐Schwartz, J., Altan‐Bonnet, N., & Patterson, G. H. (2003) · PubMed · Cited by 491
Functional studies of the kidney of living animals using multicolor two-photon microscopy
Dunn, K. W., Sandoval, R. M., Kelly, K. J., Dagher, P. C., Tanner, G. A., Atkinson, S. J., Bacallao, R. L., & Molitoris, B. A. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00159.2002 · Cited by 311 · cited 4×
“We have found that using an inverted microscope with an exteriorized left kidney (longer renal pedicle facilitates use) limits kidney movement (3).”
InfluentialSelf-citationAcute renal failure. II. Experimental models of acute renal failure: imperfect but indispensable
(2000) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.2000.278.1.f1 · Cited by 267 · cited 1×
“However, these models are not without their shortcomings as recently delineated for acute renal failure (8).”
Informatics and Quantitative Analysis in Biological Imaging
Swedlow, J. R., Goldberg, I., Brauner, E., & Sorger, P. K. (2003) · Science · doi:10.1126/science.1082602 · Cited by 253 · cited 1×
“Furthermore, exponential developments in computer sciences, specifically with applications to imaging, have removed many of the obstacles previously limiting the ability to utilize microscopy to study and quantify dynamic cellular processes (12, 14).”
Lighting up cells: labelling proteins with fluorophores.
Miyawaki, A., Sakaue-Sawano, A., & Kogure, T. (2003) · PubMed · Cited by 211
Sandoval, R. M., Kennedy, M. D., Low, P. S., & Molitoris, B. A. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00006.2004 · Cited by 149 · cited 1×
“We typically use excitation wavelengths in the 800- to 850-nm range for twophoton studies, with higher wavelengths providing less autofluorescence from pigments within proximal tubule cells (3, 10).”
Self-citationVoxx: a PC-based, near real-time volume rendering system for biological microscopy
Clendenon, J. L., Phillips, C. L., Sandoval, R. M., Fang, S., & Dunn, K. W. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2002.282.1.c213 · Cited by 125 · cited 2×
“Second, improved detectors with increased sensitivity, enhanced software and faster hardware, and new computational algorithms for 3D analysis and quantification have allowed for more rapid, sensitive, and accurate data gathering, visualization, and interpretation (2).”
Self-citationVisualizing Signals Moving in Cells
Weijer, C. J. (2003) · Science · doi:10.1126/science.1082830 · Cited by 109 · cited 1×
“Furthermore, exponential developments in computer sciences, specifically with applications to imaging, have removed many of the obstacles previously limiting the ability to utilize microscopy to study and quantify dynamic cellular processes (12, 14).”
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
The Proximal Tubule and Albuminuria: Really!
Dickson, L. E., Wagner, M. C., Sandoval, R. M., & Molitoris, B. A. (2014) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013090950 · Cited by 261
Self-citationStructural Organization of the Mammalian Kidney
Kriz, W., & Kaissling, B. (2013) · Seldin and Giebisch's The Kidney · doi:10.1016/b978-0-12-381462-3.00020-3 · Cited by 221
In vivo multiphoton imaging of mitochondrial structure and function during acute kidney injury
Hall, A. M., Rhodes, G. J., Sandoval, R. M., Corridon, P. R., & Molitoris, B. A. (2013) · Kidney International · doi:10.1038/ki.2012.328 · Cited by 215
Self-citationCarriles, R., Schafer, D. N., Sheetz, K. E., Field, J. J., Cisek, R., Barzda, V., Sylvester, A. W., & Squier, J. A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3184828 · Cited by 170
Quantitative imaging of basic functions in renal (patho)physiology
Kang, J. J., Toma, I., Sipos, A., McCulloch, F., & Peti-Peterdi, J. (2006) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00521.2005 · Cited by 161
“Multiphoton microscopy is a state-of-the-art imaging technique which can provide high-resolution images from deep optical sections of the living tissue, including the kidney (18).”
Influential
Metadata
- Authors
- Molitoris, B. A., & Sandoval, R. M.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 2005-06
- Volume
- 288
- Issue
- 6
- Pages
- F1084-F1089
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2096613434
- Cited by
- 171
- References
- 14
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.