The DOI matches its Crossref record.
Analysis and modeling of the primary cilium bending response to fluid shear
Abstract
Since a nonmotile, primary (9 + 0) cilium projects from most mammalian kidney epithelial cells into the tubule lumen, where it is exposed to fluid motion, the present study examined primary cilium response to fluid shear stress. The reversible, large-angle bending of the primary cilium upon exposure to fluid shear forces (10(-11)-10(-10) N.m2 = 10(-8)-10(-7) dyn/cm) was characterized in vitro using videomicroscopic side views of PtK1 cells, and the cilium was then mathematically modeled as a cantilevered beam. The flexural rigidity of the primary cilium was calculated to be 3.1 +/- 0.8 x 10(-23) N.m2 with a corrected quadruple integration approach and 1.4-1.6 x 10(-23) N.m2 with the "heavy elastica" theory. Comparison of theoretical profiles to the experimental bending responses of cilia established the validity of the "heavy elastica" model; this model, in turn, was used to predict primary cilium bending behavior under representative conditions in the rat nephron. The results of the study are consistent with the hypothesis that primary cilia serve a mechanosensory function in kidney epithelial cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of Structure and Function of Mammalian Cilia
Satir, P., & Christensen, S. T. (2007) · Annual Review of Physiology · doi:10.1146/annurev.physiol.69.040705.141236 · Cited by 1,142
Yoder, B. K., Hou, X., & Guay-Woodford, L. M. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000029587.47950.25 · Cited by 935
Bending the MDCK Cell Primary Cilium Increases Intracellular Calcium
Praetorius, H. A., & Spring, K. R. (2001) · Journal of Membrane Biology · doi:10.1007/s00232-001-0075-4 · Cited by 828
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
Cell Mechanics: Integrating Cell Responses to Mechanical Stimuli
Janmey, P. A., & McCulloch, C. A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151927 · Cited by 630
Metadata
- Authors
- Schwartz, E. A., Leonard, M. L., Bizios, R., & Bowser, S. S.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 1997-01-01
- Volume
- 272
- Issue
- 1
- Pages
- F132-F138
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2183960667
- Cited by
- 227
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis and modeling of the primary cilium bending response to fluid shear. https://app.cochat.ai/papers/10.1152/ajprenal.1997.272.1.f132
- The paper
- Schwartz, E. A., Leonard, M. L., Bizios, R., & Bowser, S. S. (1997). Analysis and modeling of the primary cilium bending response to fluid shear. American Journal of Physiology-Renal Physiology. https://doi.org/10.1152/ajprenal.1997.272.1.f132
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.