Esophageal and pleural pressures in man, upright and supine
The DOI matches its Crossref record.
Abstract
To assess the reliability of esophageal sampling of pleural pressure, both pressures were recorded simultaneously in seven subjects in the upright posture and, in five of these, in the supine posture. Esophageal pressure was obtained with air-containing latex balloons and pleural pressure was recorded from catheters introduced into the intrapleural space. Pneumothorax volumes were estimated to be between 5 and 350 ml. The closest correspondence between the pressures was observed in the upright posture. Expressing the difference in the amplitude of the respiratory excursions as the percentage of deviation of esophageal from pleural pressures, in the upright posture individual values ranged from +20 to -18, while the average value for the group did not differ significantly from 0. On the other hand, in the supine position individual variation was greater (range +60 to -25) and, on the average, esophageal pressure amplitudes were larger (average +27 during quiet breathing) than pleural pressure amplitudes. Submitted on August 22, 1958
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hemodynamic effects of increased abdominal pressure
Kashtan, J., Green, J. F., Parsons, E. Q., & Holcroft, J. W. (1981) · Journal of Surgical Research · doi:10.1016/0022-4804(81)90156-6 · Cited by 455
Impact of obesity on respiratory function
LITTLETON, S. W. (2012) · Respirology · doi:10.1111/j.1440-1843.2011.02096.x · Cited by 398
Computational modeling of cardiovascular response to orthostatic stress
Heldt, T., Shim, E. B., Kamm, R. D., & Mark, R. G. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00241.2001 · Cited by 303
Sahetya, S. K., Goligher, E. C., & Brower, R. G. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201610-2035ci · Cited by 223
THE RELATIONSHIP OF OXYGEN COST OF BREATHING TO RESPIRATORY MECHANICAL WORK AND RESPIRATORY FORCE
McGregor, M., & Becklake, M. R. (1961) · Journal of Clinical Investigation · doi:10.1172/jci104336 · Cited by 199
“Mead and Gaensler (3) have reported that the esophageal pressure fluctuation may exceed the simultaneous pleural pres-”
BackgroundMethod
Metadata
- Authors
- Mead, J., & Gaensler, E. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1959-01-01
- Volume
- 14
- Issue
- 1
- Pages
- 81-83
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2175054961
- Cited by
- 176
- References
- 0
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.