The DOI matches its Crossref record.
Improved technique for estimating pleural pressure from esophageal balloons
Abstract
Esophageal pressure has been measured in eight healthy men during breath holding (glottis open) at various fixed lung volumes with a rubber balloon (length: 10 cm; perimeter: 3.5 cm; wall thickness: ca. 0.06 mm) containing various volumes of air. The tip of the balloon was placed at a constant distance of 45 cm from the nares. Esophageal pressure was found to increase with balloon volume at all lung volumes but not uniformly, the effect of balloon volume being greatest at both extremes of the vital capacity. As a result, lung volume-pressure curves obtained from balloons containing volumes of gas such as are commonly used are distorted. One can avoid these distortions by repeating measurements at different balloon volumes and extrapolating esophageal pressure to zero balloon volume, or by making measurements at very small balloon volumes. A close approximation of the extrapolated pressures was obtained with the present balloon containing 0.2 ml air. The esophageal pressures at or near zero balloon volume probably reflect closely local absolute pleural pressures over the full vital capacity range in some subjects and above 20% of the vital capacity in most subjects. lung volume-pressure curves Submitted on August 13, 1963
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical ventilation guided by esophageal pressure in acute lung injury.
Talmor, D., Sarge, T., Malhotra, A., O'Donnell, C. R., Ritz, R., Lisbon, A., Novack, V., & Loring, S. H. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708638 · Cited by 1,149
Regional distribution of inspired gas in the lung.
Milic-Emili, J., Henderson, J. A., Dolovich, M. B., Trop, D., & Kaneko, K. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.3.749 · Cited by 762
Self-citationEsophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Contractile Properties of the Human Diaphragm during Chronic Hyperinflation
Similowski, T., Yan, S., Gauthier, A. P., Macklem, P. T., & Bellemare, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199109263251304 · Cited by 473
Sciurba, F. C., Rogers, R. M., Keenan, R. J., Slivka, W. A., Gorcsan, J., Ferson, P. F., Holbert, J. M., Brown, M. L., & Landreneau, R. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341704 · Cited by 462
Metadata
- Authors
- Milic-Emili, J., Mead, J., Turner, J. M., & Glauser, E. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1964-03-01
- Volume
- 19
- Issue
- 2
- Pages
- 207-211
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2272789179
- Cited by
- 863
- References
- 0
- FWCI
- 19.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved technique for estimating pleural pressure from esophageal balloons. https://app.cochat.ai/papers/10.1152/jappl.1964.19.2.207
- The paper
- Milic-Emili, J., Mead, J., Turner, J. M., & Glauser, E. M. (1964). Improved technique for estimating pleural pressure from esophageal balloons. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1964.19.2.207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.