Comparison of maximal oxygen uptake values determined by predicted and actual methods
The DOI matches its Crossref record.
Abstract
Twenty-four male subjects aged 17–33 were given three direct tests of maximal oxygen uptake and one indirect test. The direct tests were those of Mitchell, Sproule, and Chapman (treadmill); Taylor, Buskirk, and Henschel (treadmill); and Åstrand (bicycle ergometer). The indirect test was the Åstrand-Ryhming nomogram (bicycle ergometer) employing heart rate response to submaximal work. In addition, the Johnson, Brouha, and Darling physical fitness test was administered. The two treadmill tests and the indirect test yielded significantly higher mean values than did the direct bicycle test. However no other significant differences in mean values occurred. Correlation coefficients between the various oxygen uptake tests as well as the fitness test were all found to be significant (.62–.83), i.e., greater than zero. No correlation obtained proved to be significantly greater than any other. The results indicate that direct treadmill tests, employing greater muscle mass, yield higher maximal oxygen uptake values (8%) than does the direct bicycle ergometer test. The Åstrand-Ryhming nomogram appears to produce a good estimation of maximal oxygen uptake, in a population unaccustomed to cycling. erobic capacity; exercise; heart rate Submitted on September 17, 1964
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Submaximal Exercise Testing: Clinical Application and Interpretation
Noonan, V., & Dean, E. (2000) · Physical Therapy · doi:10.1093/ptj/80.8.782 · Cited by 637
Measurement of the maximum oxygen uptake V̇ o 2max : V̇ o 2peak is no longer acceptable
Poole, D. C., & Jones, A. M. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2016 · Cited by 533
Validity of criteria for establishing maximal O2 uptake during ramp exercise tests
Poole, D. C., Wilkerson, D. P., & Jones, A. M. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0596-3 · Cited by 417
Physical and Physiological Profiles of Taekwondo Athletes
Bridge, C. A., Ferreira da Silva Santos, J., Chaabène, H., Pieter, W., & Franchini, E. (2014) · Sports Medicine · doi:10.1007/s40279-014-0159-9 · Cited by 386
Physical fitness is a major determinant of femoral neck and lumbar spine bone mineral density.
Pocock, N. A., Eisman, J. A., Yeates, M. G., Sambrook, P. N., & Eberl, S. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112618 · Cited by 278
Metadata
- Authors
- Glassford, R. G., Baycroft, G. H. Y., Sedgwick, A. W., & Macnab, R. B. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1965-05-01
- Volume
- 20
- Issue
- 3
- Pages
- 509-513
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2187286712
- Cited by
- 136
- References
- 0
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of maximal oxygen uptake values determined by predicted and actual methods. https://app.cochat.ai/papers/10.1152/jappl.1965.20.3.509
- The paper
- Glassford, R. G., Baycroft, G. H. Y., Sedgwick, A. W., & Macnab, R. B. J. (1965). Comparison of maximal oxygen uptake values determined by predicted and actual methods. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1965.20.3.509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.