Cited by 533Cardiovascular and exercise physiologySports Performance and TrainingPhysical Activity and Health

Measurement of the maximum oxygen uptake V̇ o 2max : V̇ o 2peak is no longer acceptable

Poole, David C., Jones, Andrew M.·2017·Journal of Applied Physiology

Abstract

The maximum rate of O 2 uptake (i.e., V̇o 2max ), as measured during large muscle mass exercise such as cycling or running, is widely considered to be the gold standard measurement of integrated cardiopulmonary-muscle oxidative function. The development of rapid-response gas analyzers, enabling measurement of breath-by-breath pulmonary gas exchange, has facilitated replacement of the discontinuous progressive maximal exercise test (that produced an unambiguous V̇o 2 -work rate plateau definitive for V̇o 2max ) with the rapidly incremented or ramp testing protocol. Although this is more suitable for clinical and experimental investigations and enables measurement of the gas exchange threshold, exercise efficiency, and V̇o 2 kinetics, a V̇o 2 -work rate plateau is not an obligatory outcome. This shortcoming has led to investigators resorting to so-called secondary criteria such as respiratory exchange ratio, maximal heart rate, and/or maximal blood lactate concentration, the acceptable values of which may be selected arbitrarily and result in grossly inaccurate V̇o 2max estimation. Whereas this may not be an overriding concern in young, healthy subjects with experience of performing exercise to volitional exhaustion, exercise test naïve subjects, patient populations, and less motivated subjects may stop exercising before their V̇o 2max is reached. When V̇o 2max is a or the criterion outcome of the investigation, this represents a major experimental design issue. This CORP presents the rationale for incorporation of a second, constant work rate test performed at ~110% of the work rate achieved on the initial ramp test to resolve the classic V̇o 2 -work rate plateau that is the unambiguous validation of V̇o 2max . The broad utility of this procedure has been established for children, adults of varying fitness, obese individuals, and patient populations.

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01063.2016

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • All included participants fulfilled the maximal effort criteria: heart rate ≤10 beats/min or ≤5% of age-predicted maximum, blood lactate ≥8 mmol/L, and respiratory exchange ratio >1.10.

    “All the included participants fulfilled the maximal effort criteria: (1) HR ≤ 10 beats/min or ≤5% of the age-predicted (220 - age) maximum, (2) bLa ≥ 8 mmol/L, and (3) respiratory exchange ratio > 1.10 [27].”
  • VO2max was considered valid when a plateau in VO2 occurred despite increasing speed or incline, supported by a respiratory exchange ratio ≥ 1.10, RPE > 16, exercise duration > 6 min, and a maximal HR within ±10-15 bpm of the age-predicted maximum.

    “VO₂max was considered valid when a plateau in VO₂ occurred despite increasing speed or incline (Howley et al. 1995), supported by a respiratory exchange ratio ≥ 1.10, RPE > 16, exercise duration > 6 min, and a maximal HR within ± 10–15 beats per minute (bpm) of the age-predicted maximum (Poole and Jones 2017).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Poole, D. C., & Jones, A. M.
Affiliations
  • Kansas State University (US)
  • University of Exeter (GB)
Corresponding author
Poole, David C.
Venue
Journal of Applied Physiology
Published
2017-04-01
Volume
122
Issue
4
Pages
997-1002
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2585625244
Cited by
533
References
58
Citations by year
2026: 58 · 2025: 70 · 2024: 43 · 2023: 53 · 2022: 54 · 2021: 60 · 2020: 61 · 2019: 54 · 2018: 55 · 2017: 25
FWCI
11.46
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
VO2max, respiratory exchange ratio, maximal heart rate, cardiopulmonary exercise testing, exercise efficiency, gas exchange threshold
MeSH terms
Exercise Test, Heart Rate, Humans, Kinetics, Oxygen, Oxygen Consumption, Pulmonary Gas Exchange, Exercise, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review