Solubility of krypton and xenon in blood, protein solutions, and tissue homogenates
The DOI matches its Crossref record.
Abstract
The solubility of krypton and xenon in human serum albumin solutions, in hemoglobin solutions, in human blood, rabbit muscle, and beef brain homogenates has been measured at 1 atm total pressure and at temperatures of 25, 30, and 37 C. The solubilities of krypton in 1 g human albumin were found to be 0.0624, 0.0412, and 0.0195 ml at 25, 30, and 37 C, respectively. The amount of xenon dissolved in 1 g human albumin was found to be 0.2382, 0.1954, and 0.1493 ml at 25, 30, and 37 C, respectively. The amount of krypton and xenon dissolved in 1 g hemoglobin at 37 C was 0.0247 and 0.3661 ml, respectively. The solubility of cyclopropane in human serum albumin and hemoglobin solutions was calculated from the literature. The solubility coefficient of krypton, xenon, and cyclopropane in these biological solutions was found to be the sum of the solubility coefficients of the respective gas in the individual components of the biological solution. The solubilities of krypton and xenon in biological solutions decrease as temperature is raised. krypton, xenon, and cyclopropane; measurements of gas solubility; human blood—krypton and xenon solubility; human albumin—krypton, xenon, and cyclopropane solubility; human hemoglobin—krypton, xenon, and cyclopropane solubility; rabbit's muscle homogenate—krypton and xenon solubility; beef's brain homogenate—krypton and xenon solubility Submitted on September 28, 1964
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood Flow in Cutaneous Tissue in Man Studied by Washout of Radioactive Xenon
SEJRSEN, P. (1969) · Circulation Research · doi:10.1161/01.res.25.2.215 · Cited by 183
The blood-gas partition coefficient of xenon may be lower than generally accepted
Goto, T., Suwa, K., Uezono, S., Ichinose, F., Uchiyama, M., & Morita, S. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.255 · Cited by 172
Horowitz, J. F., & Klein, S. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.6.e1144 · Cited by 138
“The value for l was assumed to be 10 ml/g (42) for all subjects.”
BackgroundSamra, J. S., Clark, M. L., Humphreys, S. M., MacDonald, I. A., Bannister, P. A., & Frayn, K. N. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.2.4547 · Cited by 123
Regulation of lipid metabolism in adipose tissue during early starvation
Samra, J. S., Clark, M. L., Humphreys, S. M., Macdonald, I. A., & Frayn, K. N. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.3.e541 · Cited by 68
Metadata
- Authors
- Yeh, S.-Y., & Peterson, R. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1965-09-01
- Volume
- 20
- Issue
- 5
- Pages
- 1041-1047
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2193612680
- Cited by
- 134
- References
- 0
- FWCI
- 14.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solubility of krypton and xenon in blood, protein solutions, and tissue homogenates. https://app.cochat.ai/papers/10.1152/jappl.1965.20.5.1041
- The paper
- Yeh, S.-Y., & Peterson, R. E. (1965). Solubility of krypton and xenon in blood, protein solutions, and tissue homogenates. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1965.20.5.1041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.