The DOI matches its Crossref record.
Instability of lung units with low Va/Q ratios during O2 breathing
Abstract
Using a multiple inert gas infusion method, we have observed the development of shunts during oxygen breathing in lungs which contained areas of low ventilation-perfusion ratios while breathing air. This paper gives a theoretical analysis of the factors involved. When the inspired ventilation-perfusion ratio (VaI/Q) of a lung unit is gradually reduced, a point is reached where the expired ventilation falls to zero. Such a unit will no longer eliminate gas but may continue gas uptake unless it becomes atelectatic. This critical VaI/Q is determined by the net flux of O 2, CO 2, and N2 from alveolar gas to capillary blood, and its value increases from about 0.001 to 0.1 as the inspired gas is changed from air to 100% O 2. The critical VaI/Q at any inspired O 2 concentration is raised if the O 2 or N 2 content of mixed venous blood are reduced or if N2 is replaced by a more soluble gas. In distributions of ventilation-perfusion ratios, the amount of shunt which develops during oxygen breathing depends on the degree of dispersion of the VaI ratios. The release of hypoxic vasoconstruction following O 2 administration, in general, reduces the amount of shunt.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Aubier, M., Murciano, D., Milic-Emili, J., Touaty, E., Daghfous, J., Pariente, R., & Derenne, J. P. (1980) · American Review of Respiratory Disease · doi:10.1164/arrd.1980.122.5.747 · Cited by 431
Improved oxygenation in patients with acute respiratory failure: the prone position.
Douglas, W. W., Rehder, K., Beynen, F. M., Sessler, A. D., & Marsh, H. W. (1977) · PubMed · doi:10.1164/arrd.1977.115.4.559 · Cited by 417
Prevention of atelectasis during general anaesthesia
Rothen, H. U., Sporre, B., Engberg, G., Wegenius, G., Reber, A., & Hedenstierna, G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92595-3 · Cited by 381
Sigh in Acute Respiratory Distress Syndrome
PELOSI, P., CADRINGHER, P., BOTTINO, N., PANIGADA, M., CARRIERI, F., RIVA, E., LISSONI, A., & GATTINONI, L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9802090 · Cited by 368
Metadata
- Authors
- Dantzker, D. R., Wagner, P. D., & West, J. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1975-05-01
- Volume
- 38
- Issue
- 5
- Pages
- 886-895
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2207445550
- Cited by
- 260
- References
- 0
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Instability of lung units with low Va/Q ratios during O2 breathing. https://app.cochat.ai/papers/10.1152/jappl.1975.38.5.886
- The paper
- Dantzker, D. R., Wagner, P. D., & West, J. B. (1975). Instability of lung units with low Va/Q ratios during O2 breathing. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1975.38.5.886
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.