By use of successive increments of discontinuous work with an arm-leg cycle ergometer the VO2, Q, SV, and HR were studied in six male subjects at rest and during exercise in air and in water at 18, 25, and 33 degrees C. The Q values obtained by CO2 rebreathing were reproducible. VO2 was linearly related to work with the plots for air and 33 degrees C water being similar. However, during work in 25 and 18 degrees C water, the VO2 averaged 9.0% (150 ml) and 25.3% (400 ml) higher, respectively, than values observed in 33 degrees C water, with the largest differences observed in leaner subjects. The plot of HR-VO2 was linear and almost identical during work in air and 33 degrees C water, but shifted significantly to the right in cooler water. VO2 averaged 250–700 ml higher in cold water compared to air and 33 degrees C water at a given mean heart rate. The Q vs. VO2 line was similar during work in air and in water with no effect of water or temperature. At similar levels of VO2, SV was significantly larger (P less than 0.05) in 25 and 18 degrees C water than in air or 33 degrees C water. Consequently, the reduction in heart rate during work in cold water was entirely compensated for by a proportionate increase in the SV of the heart. Q was therefore maintained at similar levels of energy expenditure in air and in 18, 25, and 30 degrees C water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Rate Monitoring: Applications and Limitations
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,166
ENERGY EXPENDITURE INDEX OF WALKING FOR NORMAL CHILDREN AND FOR CHILDREN WITH CEREBRAL PALSY
Rose, J., Gamble, J. G., Burgos, A., Medeiros, J., & Haskell, W. L. (1990) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1990.tb16945.x · Cited by 246
Human thermoregulation and the cardiovascular system
González‐Alonso, J. (2012) · Experimental Physiology · doi:10.1113/expphysiol.2011.058701 · Cited by 220
“…tachycardia, skin and core hyperthermia, but conflicting systemic and exercising limb blood flow responses compared with equivalent exercise in the cold (Claremont et al. 1975; McArdle et al. 1976; Nadel et al. 1979; Sawka et al. 1979; Montain & Coyle, 1992; GonzálezAlonso et al. 1998, 2000a).”
BackgroundMoving in extreme environments: Open water swimming in cold and warm water
Tipton, M., & Bradford, C. (2014) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-3-12 · Cited by 107
Cold-Water Effects on Energy Balance in Healthy Women During Aqua-Cycling
Metz, L., Isacco, L., Beaulieu, K., Fearnbach, S. N., Pereira, B., Thivel, D., & Duclos, M. (2021) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2020-0177 · Cited by 6
“…available 235 evidence seems to indicate an increase in EE and lipid oxidation during cold exposure (Gagnon 236 et al., 2020; Gagnon et al., 2013; McArdle et al., 1976; Timmons, Araujo, & Thomas, 1985), 237 with few studies examining the acute responses to exercise in cold water on EB (McArdle…”
Background
Metadata
- Authors
- McArdle, W. D., Magel, J. R., Lesmes, G. R., & Pechar, G. S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1976-01-01
- Volume
- 40
- Issue
- 1
- Pages
- 85-90
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2173602681
- Cited by
- 168
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metabolic and cardiovascular adjustment to work in air and water at 18, 25, and 33 degrees C. https://app.cochat.ai/papers/10.1152/jappl.1976.40.1.85
- The paper
- McArdle, W. D., Magel, J. R., Lesmes, G. R., & Pechar, G. S. (1976). Metabolic and cardiovascular adjustment to work in air and water at 18, 25, and 33 degrees C. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1976.40.1.85
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.