The DOI matches its Crossref record.
Electromyogram pattern of diaphragmatic fatigue
Abstract
We studied the effect of breathing at various levels of transdiaphragmatic pressure (Pdi) on the EMG power spectrum of the diaphragm. The diaphragmatic EMG was measured simultaneously with a bipolar esophageal electrode (EE) and surface electrode (SE) placed on the ventral portion of the sixth and seventh intercostal spaces in five normal subjects breathing at functional residual capacity (FRC) against an inspiratory resistance. During each fatigue run the subjects generated a Pdi, with each inspiration, that was 25, 50, or 75% of maximum Pdi (Pdimax) for a period up to 15 min. During runs at 50 and 75% of the Pdimax, which are known to produce fatigue, we found for both EE and SE a progressive increase in the amplitude of the low-frequency (L = 20-46.7 Hz) and a decrease in the high-frequency (H = 150-350 Hz) component of the EMG. These changes were not seen at 25% of Pdimax. The diaphragmatic H/L ratio was independent of Pdi when the diaphragm was not fatigued. H/L fell while the diaphragm performed fatiguing work and this was more rapid at higher Pdi's. It was thus concluded that frequency spectrum analysis of the EMG can detect diaphragmatic fatigue reliably, prior to the time when the diaphragm fails as a pressure generator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Effects of Ageing on the Motor Unit: A Brief Review
Doherty, T. J., Vandervoort, A. A., & Brown, W. F. (1993) · Canadian Journal of Applied Physiology · doi:10.1139/h93-029 · Cited by 358
Effect of Carbon Dioxide on Diaphragmatic Function in Human Beings
Juan, G., Calverley, P., Talamo, C., Schnader, J., & Roussos, C. (1984) · New England Journal of Medicine · doi:10.1056/nejm198404053101402 · Cited by 331
Rochester, D. F., & Arora, N. S. (1983) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)31190-7 · Cited by 221
Metadata
- Authors
- Gross, D., Grassino, A., Ross, W. R., & Macklem, P. T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1979-01-01
- Volume
- 46
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2406303709
- Cited by
- 290
- References
- 0
- FWCI
- 16.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromyogram pattern of diaphragmatic fatigue. https://app.cochat.ai/papers/10.1152/jappl.1979.46.1.1
- The paper
- Gross, D., Grassino, A., Ross, W. R., & Macklem, P. T. (1979). Electromyogram pattern of diaphragmatic fatigue. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1979.46.1.1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.