Dynamic mechanisms determine functional residual capacity in mice, Mus musculus
The DOI matches its Crossref record.
Abstract
Awake mice (22.6--32.6 g) were anesthetized intravenously during head-out body plethysmography. One minute after pentobarbital sodium anesthesia, tidal volume had fallen from 0.28 +/- 0.04 to 0.14 +/- 0.02 ml and frequency from 181 +/- 20 to 142 +/- 8. Functional residual capacity (FRC) decreased by 0.10 +/- 0.02 ml. Expiratory flow-volume curves were linear, highly repeatable, and submaximal over substantial portions of expiration in awake and anesthetized mice; and expiration was interrupted at substantial flows that abruptly fell to and crossed zero as inspiration interrupted relaxed expiration. FRC is maintained at a higher level in awake mice due to a higher tidal volume and frequency coupled with expiratory braking (persistent inspiratory muscle activity or increased glottal resistance). In anesthetized mice, the absence of braking, coupled with reductions in tidal volume and frequency and a prolonged expiratory period, leads to FRCs that approach relaxation volume (Vr). An equation in derived to express the difference between FRC and Vr in terms of the portion of tidal volume expired without braking, the slope of the linear portion of the expiratory flow-volume curve expressed as V/V, the time fraction of one respiratory cycle spent in unbraked expiration, and respiratory frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“EELV in COPD is a continuous dynamic variable that varies with the extent of EFL and time-constant abnormalities and the breathing pattern for a given ventilation, as expressed by the following equation [6]:”
From Physiology and consequences of lung hyperinflation in COPD (2006) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Still being checked.
Cited by
Physiological Parameter Values for Physiologically Based Pharmacokinetic Models
Brown, R. P., Delp, M. D., Lindstedt, S. L., Rhomberg, L. R., & Beliles, R. P. (1997) · Toxicology and Industrial Health · doi:10.1177/074823379701300401 · Cited by 1,415
Measuring the lung function in the mouse: the challenge of size
Irvin, C. G., & Bates, J. H. (2003) · Respiratory Research · doi:10.1186/rr199 · Cited by 407
Inspiratory Muscle Dysfunction and Chronic Hypercapnia in Chronic Obstructive Pulmonary Disease
Bégin, P., & Grassino, A. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.5_pt_1.905 · Cited by 312
A reevaluation of the validity of unrestrained plethysmography in mice
Lundblad, L. K. A., Irvin, C. G., Adler, A., & Bates, J. H. T. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00080.2002 · Cited by 274
Use of allometry in predicting anatomical and physiological parameters of mammals
Lindstedt, S. L., & Schaeffer, P. J. (2002) · Laboratory Animals · doi:10.1258/0023677021911731 · Cited by 237
Metadata
- Authors
- Vinegar, A., Sinnett, E. E., & Leith, D. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1979-05-01
- Volume
- 46
- Issue
- 5
- Pages
- 867-871
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W175262007
- Cited by
- 130
- References
- 0
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic mechanisms determine functional residual capacity in mice, Mus musculus. https://app.cochat.ai/papers/10.1152/jappl.1979.46.5.867
- The paper
- Vinegar, A., Sinnett, E. E., & Leith, D. E. (1979). Dynamic mechanisms determine functional residual capacity in mice, Mus musculus. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1979.46.5.867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.