Effect of acute alterations of blood volume on circulatory performance in humans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We produced left lower lobe (LLL) pneumococcal pneumonia in seven dogs and measured lung volumes and pulmonary mechanics before (day 1) and 48 h after (day 3) development of the infection. Compared with seven control dogs, total lung capacity (TLC) and functional residual capacity (FRC) decreased 550 and 140 ml, respectively, representing a 15% reduction from the initial value in both cases. Compliance measured during tidal breathing decreased by 30%, and even when corrected for the smaller FRC on day 3, specific compliance (CLsp) was reduced. At autopsy, the infected LLL had an excess weight of 89 g, and its 50% reduction in gas volume accounted for the decrease in TLC from day 1 to day 3. Compared with control dogs, there were no changes in the deflation pressure-volume curves of the noninfected lung of the pneumonia dogs. These results indicate that the reduction in TLC in bacterial lobar pneumonia was small and resulted from the reduced gas volume of the infected lobe. Assuming that the increased weight gain in the LLL represented 89 ml of exudate that filled alveoli, we propose that bacterial pneumonia reduced gas volume at FRC by filling alveoli with inflammatory exudate and further decreased TLC by preventing these alveoli from inflating. The reduced CLsp suggested nonventilation of air spaces in addition to those that were liquid filled and was consistent with nonventilation of the entire LLL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nocturnal lowering of thresholds for sweating and vasodilation
Wenger, C. B., Roberts, M. F., Stolwijk, J. A., & Nadel, E. R. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.1.15 · Cited by 75
Self-citation
Cited by
Pollock, M. L., Gaesser, G. A., Butcher, J. D., Despr??s, J.-P., Dishman, R. K., Franklin, B. A., & Garber, C. E. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199806000-00032 · Cited by 3,051
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Mechanisms and modifiers of reflex induced cutaneous vasodilation and vasoconstriction in humans
Charkoudian, N. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00298.2010 · Cited by 475
Sawka, M. N., Leon, L. R., Montain, S. J., & Sonna, L. A. (2011) · Comprehensive Physiology · doi:10.1002/cphy.c100082 · Cited by 470
Metadata
- Authors
- Fortney, S. M., Nadel, E. R., Wenger, C. B., & Bove, J. R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1981-02-01
- Volume
- 50
- Issue
- 2
- Pages
- 292-298
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2415247731
- Cited by
- 115
- References
- 1
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.