CoChat

Measurement of pleural pressure in neonates

Asher, M. I., Coates, A. L., Collinge, J. M., Milic-Emili, J. · 1982 · Journal of Applied Physiology
Cited by 107

The DOI matches its Crossref record.

Abstract

The indirect measurement of pleural pressure in neonates is obtained from measurements of esophageal pressure (Pes) with either a liquid-filled catheter or an esophageal balloon-catheter system. The purpose of this investigation was to assess the validity of the water-filled esophageal catheter by comparing the simultaneous changes in Pes and airway opening pressure (Pao) during occluded respiratory efforts. Equal changes in Pes and Pao under this condition indicate that Pes is a valid measurement of pleural pressure. In six healthy unsedated term neonates (aged 2–3 days) we measured Pes in the lower third of the esophagus with a water-filled catheter of eight French gage (FC), which has a 2-mm internal diameter. During occlusions, changes in Pes and Pao were almost identical in magnitude and timing in each body position studied (right lateral, prone, and supine). We conclude that the water-filled 8-FG esophageal catheter gives an accurate measurement of pleural pressure changes in healthy neonates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1982.52.2.491

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 107

Metadata

Authors
Asher, M. I., Coates, A. L., Collinge, J. M., & Milic-Emili, J.
Venue
Journal of Applied Physiology
Published
1982-02-01
Volume
52
Issue
2
Pages
491-494
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1892095814
Cited by
107
References
0
FWCI
1.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of pleural pressure in neonates. https://app.cochat.ai/papers/10.1152/jappl.1982.52.2.491
The paper
Asher, M. I., Coates, A. L., Collinge, J. M., & Milic-Emili, J. (1982). Measurement of pleural pressure in neonates. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.2.491

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.