Ventilatory adaptations to resistive loading during wakefulness and non-REM sleep
The DOI matches its Crossref record.
Abstract
Ventilatory and timing responses to repetitive and sustained inspiratory resistive loading were assessed in six naive male subjects during wakefulness (AW) and non-REM sleep (NREM). In five of six subjects, tidal volume (VT) was maintained or increased with repetitive five-breath loading periods during wakefulness. In these five subjects, mouth occlusion pressure (P100) increased with loading during AW (1.8 +/- 0.5 control vs. 2.2 +/- 0.4 cmH2O loaded, P less than 0.05), but not during NREM (2.1 +/- 1.5 control vs. 2.1 + 1.5 cmH2O loaded). For each state, VT and frequency (f) responses to sustained loads were similar to responses to five-breath loads. During sustained loading; a) VT increased 35% during AW, decreased 28% during NREM, b) f decreased 35% during AW, increased 6% during NREM, c) minute ventilation (VE) decreased 12% during AW, decreased 23% during NREM. Ventilatory responses persisted until arousal (0.4--1.7 min) in NREM. With repetitive loading: a) inspiratory duration (TI) increased during AW but did not change during NREM, b) “duty cycle” (TI/TT) increased with loading in both states. These findings suggest that a) NREM abolishes between-breath augmentations in P100, b) within-breath load compensation is operant during both AW (preserved VT) and NREM (failure of predicted TI prolongation) by differing mechanisms, c) arousal may be a ventilatory compensation to inspiratory resistive loading in NREM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
“Added resistive or elastic loads to the airway prompt immediate and highly variable increases in the drive to breathe in the waking state, which prevent hypoventilation; however, in sleep, these mechanical loads are not accompanied by an immediate compensatory increase in the drive to breathe, and hypoventilation ensu…”
BackgroundSelf-citationMezzanotte, W. S., Tangel, D. J., & White, D. P. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115751 · Cited by 769
Effect of Weight Loss on Upper Airway Collapsibility in Obstructive Sleep Apnea
Schwartz, A. R., Gold, A. R., Schubert, N., Stryzak, A., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.3_pt_1.494 · Cited by 477
Control of Breathing During Sleep
Phillipson, E. A., & Bowes, G. (1986) · Comprehensive Physiology · doi:10.1002/j.2040-4603.1986.tb01069.x · Cited by 335
Pathophysiology of obstructive sleep apnoea
Deegan, P., & McNicholas, W. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08071161 · Cited by 330
Metadata
- Authors
- Iber, C., Berssenbrugge, A., Skatrud, J. B., & Dempsey, J. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-03-01
- Volume
- 52
- Issue
- 3
- Pages
- 607-614
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2408188028
- Cited by
- 106
- References
- 0
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilatory adaptations to resistive loading during wakefulness and non-REM sleep. https://app.cochat.ai/papers/10.1152/jappl.1982.52.3.607
- The paper
- Iber, C., Berssenbrugge, A., Skatrud, J. B., & Dempsey, J. A. (1982). Ventilatory adaptations to resistive loading during wakefulness and non-REM sleep. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.3.607
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.