CoChat

Demonstration of failure of body plethysmography in airway obstruction

Rodenstein, D. O., Stanescu, D. C., Francis, C. · 1982 · Journal of Applied Physiology
Cited by 115

The DOI matches its Crossref record.

Abstract

To demonstrate the role of extrathoracic airways in the overestimation of lung volumes by body plethysmography in airway obstruction, we induced in six normal subjects an artificial airway stenosis by inflating a balloon in the lower trachea. We measured thoracic gas volume in a body plethysmograph simultaneously from mouth pressure (Pm) vs. plethysmographic volume (Vbox) (TGVm) and from esophageal pressure (Pes) vs. Vbox (TGVes). During control measurements there was no difference between TGVm and TGVes (P greater than 0.1) in any subject. Balloon inflation (B) resulted in a significant (P less than 0.01) decrease of specific airway conductance (sGaw) from a mean value of 0.199 +/- 0.66 (SD) to 0.025 +/- 0.01 cmH2O-1 . s-1. TGVm significantly (P less than 0.02) exceeded TGVes in every subject (mean diff 1.24 +/- 0.56 liters) and Pm lagged behind Pes. In two subjects studied at different levels of airway obstruction we found a significant (P less than 0.05) correlation between TGVm-TGVes difference and sGaw. Bypassing the extrathoracic airways by a cuffed endotracheal tube resulted in each case in a degree of airway obstruction comparable to that during balloon inflation (sGaw 0.019 +/- 0.004 cmH2O-1 . s-1), but no difference between TGVm and TGVes (P greater than 0.1). We conclude that lung volume is overestimated by plethysmography in airway obstruction. The overestimation is due to the presence of a compliant extrathoracic airway, and it probably depends on both the degree of airway obstruction and the value of compliance of the extrathoracic airway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1982.52.4.949

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 115

Metadata

Authors
Rodenstein, D. O., Stanescu, D. C., & Francis, C.
Venue
Journal of Applied Physiology
Published
1982-04-01
Volume
52
Issue
4
Pages
949-954
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1888902919
Cited by
115
References
0
FWCI
7.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Demonstration of failure of body plethysmography in airway obstruction. https://app.cochat.ai/papers/10.1152/jappl.1982.52.4.949
The paper
Rodenstein, D. O., Stanescu, D. C., & Francis, C. (1982). Demonstration of failure of body plethysmography in airway obstruction. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.4.949

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.