The DOI matches its Crossref record.
A computer linear regression model to determine ventilatory anaerobic threshold
Abstract
The anaerobic threshold has generally been determined by simple visual inspection of ventilation or other gas-exchange data obtained during incremental exercise. To establish objective criteria for the determination of anaerobic threshold, a computer algorithm has been developed that models the ventilatory response to exercise using multisegment linear regression. The best-fit regression model is chosen by minimizing the pooled residual sum of squares . The anaerobic threshold is reported as the first break point in that model. The computer-determined anaerobic threshold values for 37 subjects were compared with subjectively determined values as chosen by four independent observers. The observers' estimates, when pooled to yield a single a single value for each subject, gave a mean value for the gas-exchange anaerobic threshold of 2.26 +/- 0.69 l/min. The estimates by the computer method averaged 2.21 +/- 0.65 l/min. The correlation coefficient for these two methods was 0.94.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487
Exercise-Induced Pulmonary Arterial Hypertension
Tolle, J. J., Waxman, A. B., Van Horn, T. L., Pappagianopoulos, P. P., & Systrom, D. M. (2008) · Circulation · doi:10.1161/circulationaha.108.787101 · Cited by 357
Reproducibility of aerobic and anaerobic thresholds in 20–50 year old men
Aunola, S., & Rusko, H. (1984) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00776600 · Cited by 141
Smith, A. E., Walter, A. A., Graef, J. L., Kendall, K. L., Moon, J. R., Lockwood, C. M., Fukuda, D. H., Beck, T. W., Cramer, J. T., & Stout, J. R. (2009) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-6-5 · Cited by 123
Does Anaerobic Threshold Correlate with Maximal Lactate Steady-State?
Aunola, S., & Rusko, H. (1992) · Journal of Sports Sciences · doi:10.1080/02640419208729931 · Cited by 101
Exercise-induced oxidative stress: the effects of β-alanine supplementation in women
Smith, A. E., Stout, J. R., Kendall, K. L., Fukuda, D. H., & Cramer, J. T. (2012) · Amino Acids · doi:10.1007/s00726-011-1158-x · Cited by 62
Graef, J. L., Smith, A. E., Kendall, K. L., Fukuda, D. H., Moon, J. R., Beck, T. W., Cramer, J. T., & Stout, J. R. (2009) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-6-18 · Cited by 51
“VT was determined from a plot of ventilation (VE) against VO2 as described previously [20].”
MethodReliability of assessments of ventilatory thresholds
Prud'Homme, D., Bouchard, C., Leblance, C., Landry, F., Lortie, G., & Boulay, M. R. (1984) · Journal of Sports Sciences · doi:10.1080/02640418408729692 · Cited by 49
Metadata
- Authors
- Orr, G. W., Green, H. J., Hughson, R. L., & Bennett, G. W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-05-01
- Volume
- 52
- Issue
- 5
- Pages
- 1349-1352
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1861082135
- Cited by
- 160
- References
- 0
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.