An automated, indirect assessment of cardiac output during rest and exercise
The DOI matches its Crossref record.
Abstract
The present study describes a modification of the equilibration CO2-rebreathing technique for determining cardiac output (Q), utilizing the Beckman Metabolic Measurement Cart (MMC) to provide partial automation of the procedures described by Jones et al. (Clinical Exercise Testing. Philadelphia, PA: Saunders, 1975). Q was determined in six normal healthy males to establish the reliability of the technique at rest, and during exercise at power outputs of 49 and 98 W, or 300 and 600 kpm/min. An additional 11 patients, who were symptomatic for coronary artery disease and scheduled for right and left heart catheterization, were used in validating these procedures against Q determined by the thermodilution method. The automated CO2-rebreathing procedure was found to be reliable at rest and during exercise, and demonstrated a direct linear relationship with VO2 (r = 0.90). Also, this procedure correlated (r = 0.87) with the thermodilution method during supine rest, and both methods were quite consistent between trials within the same subject. It was concluded that the CO2-rebreathing procedure used in this study, as interfaced with the Beckman MMC, provides reasonable estimates of Q, both in patients during supine rest, and in normal healthy subjects at rest and during low to moderate levels of exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wilmore, J. H., Freund, B. J., Joyner, M. J., Hetrick, G. A., Hartzell, A. A., Strother, R. T., Ewy, G. A., & Faris, W. E. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)91070-7 · Cited by 68
Self-citationWILMORE, J. H., STANFORTH, P. R., TURLEY, K. R., GAGNON, J., DAW, E. W., LEON, A. S., RAO, D. C., SKINNER, J. S., & BOUCHARD, C. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199802000-00014 · Cited by 57
Self-citationAdes, P. A., Gunther, P. G. S., Meyer, W. L., Gibson, T. C., Maddalena, J., & Orfeo, T. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90486-k · Cited by 25
Metadata
- Authors
- Wilmore, J. H., Farrell, P. A., Norton, A. C., Cote, R. W., Coyle, E. F., Ewy, G. A., Temkin, L. P., & Billing, J. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-06-01
- Volume
- 52
- Issue
- 6
- Pages
- 1493-1497
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W157660123
- Cited by
- 45
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An automated, indirect assessment of cardiac output during rest and exercise. https://app.cochat.ai/papers/10.1152/jappl.1982.52.6.1493
- The paper
- Wilmore, J. H., Farrell, P. A., Norton, A. C., Cote, R. W., Coyle, E. F., Ewy, G. A., Temkin, L. P., & Billing, J. E. (1982). An automated, indirect assessment of cardiac output during rest and exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.6.1493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.