Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 495

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

A comparison of gas exchange indices used to detect the anaerobic threshold

Caiozzo, V. J., Davis, J. A., Ellis, J. F., Azus, J. L., Vandagriff, R., Prietto, C. A., McMaster, W. C.·1982·Journal of Applied Physiology

Abstract

This study was undertaken to determine which of four commonly used ventilatory or gas exchange indices provides the most accurate and reliable detection of the anaerobic threshold (AT). Sixteen subjects performed two cycle ergometer tests to volitional fatigue. After 4 min of unloaded cycling, the work rate was increased 20 W/min. Ventilatory and gas exchange measurements were made every 30 s throughout each test. During one of the two tests (randomly assigned), venous blood was also sampled every 30 s for subsequent determinations of blood lactate (HLa) concentration. Four ventilatory and gas exchange indices (VE, VCO2, R, VE/VO2) were used separately to detect the AT. The AT determined from systematic increases in HLa concentration was used as the criterion measure. AT values (means +/- SE) (VO2, l/min) using VE, VCO2, R, VE/VO2, and HLa were 1.79 +/- 0.11, 1.74 +/- 0.11, 1.58 +/- 0.06, 1.84 +/- 0.11, and 1.85 +/- 0.11 l/min, respectively. The highest correlation between a ventilatory or gas exchange AT and ATHLa (i.e., criterion measure) was found for VE/VO2 (r=0.93, P less than 0.001). The VE/VO2 also provided the highest test-retest correlation for detection of the AT (r = 0.93, P less than 0.001). Multiple correlational analyses did not significantly enhance detection of the AT. These results favor the use of VE/VO2 for noninvasive detection of the AT because it proved to be the most sensitive and reliable ventilatory or gas exchange index studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1982.53.5.1184

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 495

Metadata

Authors
Caiozzo, V. J., Davis, J. A., Ellis, J. F., Azus, J. L., Vandagriff, R., Prietto, C. A., & McMaster, W. C.
Venue
Journal of Applied Physiology
Published
1982-11-01
Volume
53
Issue
5
Pages
1184-1189
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2176325574
Cited by
495
References
16
FWCI
11.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of gas exchange indices used to detect the anaerobic threshold. https://app.cochat.ai/papers/10.1152/jappl.1982.53.5.1184
The paper
Caiozzo, V. J., Davis, J. A., Ellis, J. F., Azus, J. L., Vandagriff, R., Prietto, C. A., & McMaster, W. C. (1982). A comparison of gas exchange indices used to detect the anaerobic threshold. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.53.5.1184

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.