The DOI matches its Crossref record.
Determination of Anaerobic Threshold by the Ventilation Equivalent in Normal Individuals
Abstract
In 131 untrained healthy volunteers, unsteady-state upright bicycle ergometry was carried out by means of computer-assisted on-line ergospirometry. In 11 males and 4 females capillary lactate and blood gas analyses sampled simultaneously at 1-min intervals revealed that it is possible to determine the ‘anaerobic threshold’ (AT) and a ‘threshold of decompen-sated metabolic acidosis’ (TDMA) from the respiratory gas exchange by controlling the ventilation equivalent for oxygen (VE O2 = V E/V O2) and carbon dioxide (VE CO2 = V E/V CO2). There is no necessity of invasive measurements. Solely ergospirometrical tests in 66 males and 50 females, aged 20–65 years, showed the expected higher work load levels and V O2 at AT and TDMA in males. There was a significant negative correlation to age. In contrast, there are no differences with regard to sex in AT and TDMA for weight-corrected work rates. In the age group 20–39 years, AT is at about 1 W/kg body weight, TDMA at about 2 W/kg body weight. The larger maximum exercise capacity weight corrected for males (3 W/kg) in comparison to females (2.6 W/kg) was dependent on a greater capability in the range of maximum exertion and not on a different level of AT and TDMA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Binder, R. K., Wonisch, M., Corra, U., Cohen-Solal, A., Vanhees, L., Saner, H., & Schmid, J.-P. (2008) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328304fed4 · Cited by 487
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
Reproducibility of aerobic and anaerobic thresholds in 20–50 year old men
Aunola, S., & Rusko, H. (1984) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00776600 · Cited by 141
Metadata
- Authors
- Reinhard, U., Müller, P. H., & Schmülling, R.-M.
- Venue
- Respiration
- Publisher
- S. Karger AG
- Published
- 2009-01-14
- Volume
- 38
- Issue
- 1
- Pages
- 36-42
- ISSN
- 0025-7931 (ISSN-L)
- 1423-0356
- OpenAlex
- W2027570227
- Cited by
- 271
- References
- 0
- FWCI
- 25.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- karger.com/pages/terms-and-conditions (vor)
- karger.com/pages/terms-and-conditions (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Anaerobic Threshold by the Ventilation Equivalent in Normal Individuals. https://app.cochat.ai/papers/10.1159/000194056
- The paper
- Reinhard, U., Müller, P. H., & Schmülling, R.-M. (2009). Determination of Anaerobic Threshold by the Ventilation Equivalent in Normal Individuals. Respiration. https://doi.org/10.1159/000194056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.