CoChat

Frequency dependence of plethysmographic volume in healthy and asthmatic subjects

Rodenstein, D. O., Stanescu, D. C. · 1983 · Journal of Applied Physiology
Cited by 77

The DOI matches its Crossref record.

Abstract

In airway obstruction, thoracic gas volume derived from mouth pressure vs. plethysmographic volume changes (TGVm) is overestimated, whereas TGVes, derived from esophageal pressure vs. plethysmographic volume changes, is not (J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 52: 939–954, 1982). The reason appears to be that mouth pressure swings are less than alveolar pressure swings. We measured TGVm and TGVes in six normal subjects and in nine asthmatic patients before and during bronchospasm, while panting at the same lung volume at 0.8 Hz (low), 2–2.5 Hz (medium), and 4.5–5 Hz (high). No difference was observed between TGVm and TGVes (P greater than 0.05) at any frequency (f) in normal subjects or asthmatics before bronchospasm. During bronchospasm, TGVm and TGVes were similar at low f. However, TGVm increased from 5.66 +/- 1.16 (SD) liters at low f to 6.50 +/- 1.71 liters at medium f (P less than 0.01), resulting in a TGVm 1.16 +/- 0.95 liters higher than TGVes (P less than 0.01). In three asthmatics during bronchospasm, mean TGVm-TGVes difference was 0.01 liter at low f, 0.26 liter at medium f, and 0.73 liter at high f. Surprisingly TGVes was in average 5% higher at low f than at medium or high f, both in normal subjects and asthmatics. A similar pattern was observed for TGVm, except in asthmatics during bronchospasm. We conclude that in airway obstruction overestimation of TGVm is frequency dependent and can be avoided by panting at low f. However, at this f TGV is 5% larger than at higher f, difference which is not related to airway obstruction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1983.54.1.159

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 77

Metadata

Authors
Rodenstein, D. O., & Stanescu, D. C.
Venue
Journal of Applied Physiology
Published
1983-01-01
Volume
54
Issue
1
Pages
159-165
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2162660637
Cited by
77
References
0
FWCI
3.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Frequency dependence of plethysmographic volume in healthy and asthmatic subjects. https://app.cochat.ai/papers/10.1152/jappl.1983.54.1.159
The paper
Rodenstein, D. O., & Stanescu, D. C. (1983). Frequency dependence of plethysmographic volume in healthy and asthmatic subjects. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1983.54.1.159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.