Induction of airway collapse with subatmospheric pressure in awake patients with sleep apnea
The DOI matches its Crossref record.
Abstract
To determine whether the pharyngeal airway is abnormal in awake patients with obstructive sleep apnea (OSA), we measured the ability of the pharyngeal airway to resist collapse from subatmospheric pressure applied to the nose in awake subjects, 12 with OSA and 12 controls. Subatmospheric pressure was applied to subjects placed in the supine position through a tightly fitting face mask. We measured airflow at the mask as well as mask, pharyngeal, and esophageal pressures. Ten patients developed airway obstruction when subatmospheric pressures between 17 and 40 cmH2O were applied. Obstruction did not occur in two patients with the least OSA. Obstruction did not occur in 10 controls; one obese control subject developed partial airway obstruction when -52 cmH2O was applied as did another with -41 cmH2O. We conclude that patients with significant OSA have an abnormal airway while they are awake andthat application of subatmospheric pressure may be a useful screening test to detect OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
Schwab, R. J., Gefter, W. B., Hoffman, E. A., Gupta, K. B., & Pack, A. I. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1385 · Cited by 505
Effect of Weight Loss on Upper Airway Collapsibility in Obstructive Sleep Apnea
Schwartz, A. R., Gold, A. R., Schubert, N., Stryzak, A., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.3_pt_1.494 · Cited by 477
Facial morphology and obstructive sleep apnea
Lowe, A. A., Santamaria, J. D., Fleetham, J. A., & Price, C. (1986) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(86)90108-3 · Cited by 336
Sanders, M. H., & Kern, N. (1990) · Chest · doi:10.1378/chest.98.2.317 · Cited by 290
Eltayara, L., Becklake, M. R., Volta, C. A., & Milic-Emili, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970362 · Cited by 277
Sancho, J., Servera, E., Díaz, J., & Marín, J. (2004) · Chest · doi:10.1378/chest.125.4.1400 · Cited by 204
Schwab, R. J. (1998) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70430-5 · Cited by 200
Pharyngeal compliance in snoring subjects with and without obstructive sleep apnea.
Brown, I. G., Bradley, T. D., Phillipson, E. A., Zamel, N., & Hoffstein, V. (1985) · PubMed · doi:10.1164/arrd.1985.132.2.211 · Cited by 193
Berthon-Jones, M., & Sullivan, C. E. (1987) · PubMed · doi:10.1164/arrd.1987.135.1.144 · Cited by 181
Horner, R. L., Innes, J. A., Morrell, M. J., Shea, S. A., & Guz, A. (1994) · The Journal of Physiology · doi:10.1113/jphysiol.1994.sp020118 · Cited by 179
Detection of expiratory flow limitation during exercise in COPD patients
Koulouris, N. G., Dimopoulou, I., Valta, P., Finkelstein, R., Cosio, M. G., & Milic-Emili, J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.723 · Cited by 161
“(29) measured the ability of the pharyngeal airway to resist collapse in the face of NEP in awake supine patients with OSA.”
BackgroundUpper airway surgery for obstructive sleep apnea
Sher, A. E. (2002) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0242 · Cited by 124
Malhotra, A., Pillar, G., Fogel, R., Beauregard, J., Edwards, J., & White, D. P. (2001) · Chest · doi:10.1378/chest.120.1.156 · Cited by 102
Metadata
- Authors
- Suratt, P. M., Wilhoit, S. C., & Cooper, K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1984-07-01
- Volume
- 57
- Issue
- 1
- Pages
- 140-146
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2178066887
- Cited by
- 109
- References
- 0
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.