Clearance of mucus by simulated cough
The DOI matches its Crossref record.
Abstract
We examined the relationship between mucus rheology, depth of mucus layer, and clearance by simulated cough. A model trachea was constructed of rigid Plexiglas of rectangular cross section (1 X 2 X 35 cm). The bottom of the trachea was lined with mucus simulants, gels prepared from locust bean gum cross-linked with sodium borate. Cough was simulated by opening a solenoid valve connecting the model trachea to a pressurized tank. An upstream flow-constrictive element was used to shape the flow profile of the simulated cough to approximate the pattern seen in a normal adult. Clearance of mucus was quantitated by observing the movement of contrasting marker particles floating in the mucus layer. The median particle displacement per cough maneuver was defined as the clearance index (CI). We found that CI for any initial depth of mucus increased with the driving pressure in the tank. For a given driving pressure, CI increased linearly with increasing mucus depth. For a given driving pressure and depth, CI decreased with increasing mucus cross-link density. For mucus samples with comparable levels of dynamic viscosity, samples with higher elasticity cleared less well. Mucus clearance was associated with transient wave formation in the lining layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Respiratory Care of the Patient with Duchenne Muscular Dystrophy: ATS Consensus Statement
(2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200307-885st · Cited by 733
Mechanical Insufflation-Exsufflation
Bach, J. R. (1993) · Chest · doi:10.1378/chest.104.5.1553 · Cited by 450
Physiology and pathophysiology of human airway mucus
Hill, D. B., Button, B., Rubinstein, M., & Boucher, R. C. (2022) · Physiological Reviews · doi:10.1152/physrev.00004.2021 · Cited by 366
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
A Pilot Study of Aerosolized Amiloride for the Treatment of Lung Disease in Cystic Fibrosis
Knowles, M. R., Church, N. L., Waltner, W. E., Yankaskas, J. R., Gilligan, P., King, M., Edwards, L. J., Helms, R. W., & Boucher, R. C. (1990) · New England Journal of Medicine · doi:10.1056/nejm199004263221704 · Cited by 356
Self-citationGlobal Physiology and Pathophysiology of Cough
McCool, F. D. (2006) · Chest · doi:10.1378/chest.129.1_suppl.48s · Cited by 298
Mick, P., & Murphy, R. (2020) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-020-00424-7 · Cited by 224
Role of the physiochemical properties of mucus in the protection of the respiratory epithelium
Girod, S., Zahm, J., Plotkowski, C., Beck, G., & Puchelle, E. (1992) · European Respiratory Journal · doi:10.1183/09031936.93.05040477 · Cited by 220
Metadata
- Authors
- King, M., Brock, G., & Lundell, C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-06-01
- Volume
- 58
- Issue
- 6
- Pages
- 1776-1782
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2144440338
- Cited by
- 221
- References
- 0
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.