CoChat

Aerosol-generating otolaryngology procedures and the need for enhanced PPE during the COVID-19 pandemic: A literature review

Open access
Mick, Paul, Murphy, Russell · 2020 · Journal of Otolaryngology - Head & Neck Surgery
Cited by 224

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Abstract

Background: Adequate personal protective equipment is needed to reduce the rate of transmission of COVID-19 to health care workers. Otolaryngology groups are recommending a higher level of personal protective equipment for aerosol-generating procedures than public health agencies. The objective of the review was to provide evidence that a.) demonstrates which otolaryngology procedures are aerosol-generating, and that b.) clarifies whether the higher level of PPE advocated by otolaryngology groups is justified. Main body: Health care workers in China who performed tracheotomy during the SARS-CoV-1 epidemic had 4.15 times greater odds of contracting the virus than controls who did not perform tracheotomy (95% CI 2.75–7.54). No other studies provide direct epidemiological evidence of increased aerosolized transmission of viruses during otolaryngology procedures. Experimental evidence has shown that electrocautery, advanced energy devices, open suctioning, and drilling can create aerosolized biological particles. The viral load of COVID-19 is highest in the upper aerodigestive tract, increasing the likelihood that aerosols generated during procedures of the upper aerodigestive tract of infected patients would carry viral material. Cough and normal breathing create aerosols which may increase the risk of transmission during outpatient procedures. A significant proportion of individuals infected with COVID-19 may not have symptoms, raising the likelihood of transmission of the disease to inadequately protected health care workers from patients who do not have probable or confirmed infection. Powered air purifying respirators, if used properly, provide a greater level of filtration than N95 masks and thus may reduce the risk of transmission. Conclusion: Direct and indirect evidence suggests that a large number of otolaryngology-head and neck surgery procedures are aerosol generating. Otolaryngologists are likely at high risk of contracting COVID-19 during aerosol generating procedures because they are likely exposed to high viral loads in patients infected with the virus. Based on the precautionary principle, even though the evidence is not definitive, adopting enhanced personal protective equipment protocols is reasonable based on the evidence. Further research is needed to clarify the risk associated with performing various procedures during the COVID-19 pandemic, and the degree to which various personal protective equipment reduces the risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40463-020-00424-7

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Metadata

Authors
Mick, P., & Murphy, R.
Venue
Journal of Otolaryngology - Head & Neck Surgery
Published
2020-01
Volume
49
Issue
1
Pages
29-29
ISSN
  • 1916-0208 (ISSN-L)
  • 1916-0216
OpenAlex
W3023003554
Cited by
224
References
53
FWCI
25.00
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aerosol-generating otolaryngology procedures and the need for enhanced PPE during the COVID-19 pandemic: A literature review. https://app.cochat.ai/papers/10.1186/s40463-020-00424-7
The paper
Mick, P., & Murphy, R. (2020). Aerosol-generating otolaryngology procedures and the need for enhanced PPE during the COVID-19 pandemic: A literature review. Journal of Otolaryngology - Head & Neck Surgery. https://doi.org/10.1186/s40463-020-00424-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.