The DOI matches its Crossref record.
Analysis of the behavior of the respiratory system with constant inspiratory flow
Abstract
For a respiratory system with constant compliance and resistance a constant flow can occur during part or all of inspiration in two situations: when the flow is constrained to be constant throughout inspiration, such as is the case with some mechanical ventilators, and when the applied pressure is a ramp (i.e., increasing constantly with time), which may occur during mechanical ventilation and spontaneous breathing. After initial transients in pressure and flow, respectively, have decayed away both situations result in linear volume-time and pressure-time relationships. The slope of the corresponding pressure-volume line then yields an estimate of the total compliance of the respiratory system, and the intercept, divided by the constant flow, provides the total resistance. We have shown theoretically that, for a model composed of two compartments in parallel, the total compliance is the same as the static compliance and equals the sum of the compliances of the two compartments. Furthermore, this compliance is independent of the breathing frequency. However, the total resistance is, in general, a function of both the resistances and the compliances. When the time constants of the two compartments are equal the total resistance assumes its minimum value and becomes independent of the compliances. This minimum value of resistance can be obtained, regardless of the time constants, by dividing the immediate drop in airway opening pressure, obtained after occluding during steady state inspiration, by the inspiratory flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Beydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
VASSILAKOPOULOS, T., ZAKYNTHINOS, S., & ROUSSOS, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9710084 · Cited by 297
Stahl, C. A., Möller, K., Schumann, S., Kuhlen, R., Sydow, M., Putensen, C., & Guttmann, J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000227220.67613.0d · Cited by 289
Riva, D. R., Magalhães, C. B., Lopes, A. A., Lanças, T., Mauad, T., Malm, O., Valença, S. S., Saldiva, P. H., Faffe, D. S., & Zin, W. A. (2011) · Inhalation Toxicology · doi:10.3109/08958378.2011.566290 · Cited by 282
Respiratory system mechanics in sedated, paralyzed, morbidly obese patients
Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., & Gattinoni, L. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.811 · Cited by 273
Metadata
- Authors
- Bates, J. H., Rossi, A., & Milic-Emili, J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-06-01
- Volume
- 58
- Issue
- 6
- Pages
- 1840-1848
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2294901645
- Cited by
- 441
- References
- 0
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of the behavior of the respiratory system with constant inspiratory flow. https://app.cochat.ai/papers/10.1152/jappl.1985.58.6.1840
- The paper
- Bates, J. H., Rossi, A., & Milic-Emili, J. (1985). Analysis of the behavior of the respiratory system with constant inspiratory flow. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.58.6.1840
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.