Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Respiratory system mechanics in sedated, paralyzed, morbidly obese patients

Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., Gattinoni, L.·1997·Journal of Applied Physiology

Abstract

Pelosi, P., M. Croci, I. Ravagnan, M. Cerisara, P. Vicardi, A. Lissoni, and L. Gattinoni. Respiratory system mechanics in sedated, paralyzed, morbidly obese patients J. Appl. Physiol. 82(3): 811–818, 1997.—The effects of inspiratory flow and inflation volume on the mechanical properties of the respiratory system in eight sedated and paralyzed postoperative morbidly obese patients (aged 37.6 ± 11.8 yr who had never smoked and had normal preoperative seated spirometry) were investigated by using the technique of rapid airway occlusion during constant-flow inflation. With the patients in the supine position, we measured the interrupter resistance (Rint,rs), which in humans probably reflects airway resistance, the “additional” resistance (ΔRrs) due to viscoelastic pressure dissipation and time-constant inequalities, and static respiratory elastance (Est,rs). Intra-abdominal pressure (IAP) was measured by using a bladder catheter, and functional residual capacity was measured by the helium-dilution technique. The results were compared with a previous study on 16 normal anesthetized paralyzed humans. Compared with normal persons, we found that in obese subjects: 1) functional residual capacity was markedly lower (0.645 ± 0.208 liter) and IAP was higher (24 ± 2.2 cmH 2 O); 2) alveolar-arterial oxygenation gradient was increased (178 ± 59 mmHg); 3) the volume-pressure curve of the respiratory system was curvilinear with an “inflection” point; 4) Est,rs, Rint,rs, and ΔRrs were higher than normal (29.3 ± 5.04 cmH 2 O/l, 5.9 ± 2.4 cmH 2 O ⋅ l−1 ⋅ s, and 6.4 ± 1.6 cmH 2 O ⋅ l−1 ⋅ s, respectively); 5) Rint,rs increased with increasing inspiratory flow, Est,rs did not change, and ΔRrs decreased progressively; and 6) with increasing inflation volume, Rint,rs and Est,rs decreased, whereas ΔRrs rose progressively. Overall, our data suggest that obese subjects during sedation and paralysis are characterized by hypoxemia and marked alterations of the mechanical properties of the respiratory system, largely explained by a reduction in lung volume due to the excessive unopposed IAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1997.82.3.811

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 273

Metadata

Authors
Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., & Gattinoni, L.
Venue
Journal of Applied Physiology
Published
1997-03-01
Volume
82
Issue
3
Pages
811-818
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2174721290
Cited by
273
References
24
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Respiratory system mechanics in sedated, paralyzed, morbidly obese patients. https://app.cochat.ai/papers/10.1152/jappl.1997.82.3.811
The paper
Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., & Gattinoni, L. (1997). Respiratory system mechanics in sedated, paralyzed, morbidly obese patients. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.82.3.811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.