Effect of graded erythrocythemia on cardiovascular and metabolic responses to exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The effects of graded induced erythrocythemia on cardiovascular and metabolic responses to intense treadmill running were studied in four highly trained endurance runners. Three autologous infusions of 1 unit (U) whole blood (450 ml/U) were administered sequentially 2–7 days apart. Maximal O2 consumption (VO2max) increased from 5.04 l/min at control (C) to 5.24 l/min after 2 U (R2) and 5.38 l/min after 3 U (R3). Cardiac output during treadmill running at 91% control VO2max was 28.2 l/min at C, 29.8 l/min at R2, and 33.1 l/min at R3. Corresponding heart rates were unchanged, and stroke volume was increased at R3. Peak lactate concentration was reduced, and arterial acid-base status improved at R2 and R3 after standardized bouts of intense exercise. Arterial blood pressures and electrocardiograms during exercise were not affected by erythrocythemia. We conclude that the reinfusion of up to 3 U of autologous blood into highly trained endurance runners who have normal hematology does not adversely affect their cardiovascular response to maximal exercise. In addition, the increases in VO2max following reinfusion of 2 U, and again after 3 U, suggest that the aerobic power of the working muscles was not surpassed at these levels of erythrocythemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparing Individual Means in the Analysis of Variance
Tukey, J. W. (1949) · Biometrics · doi:10.2307/3001913 · Cited by 4,246
THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1
Mitchell, J. H., Sproule, B. J., & Chapman, C. B. (1958) · Journal of Clinical Investigation · doi:10.1172/jci103636 · Cited by 516
Cited by
Limiting factors for maximum oxygen uptake and determinants of endurance performance
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00012 · Cited by 2,410
Evidence that a central governor regulates exercise performance during acute hypoxia and hyperoxia
Noakes, T. D., Peltonen, J. E., & Rusko, H. K. (2001) · Journal of Experimental Biology · doi:10.1242/jeb.204.18.3225 · Cited by 247
Importance of hemoglobin concentration to exercise: Acute manipulations
Calbet, J. A. L., Lundby, C., Koskolou, M., & Boushel, R. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.01.014 · Cited by 195
“In the 1960s and 1970s, new blood transfusion experiments to explore the influence of blood volume and Hb concentration on the hemodynamics during submaximal and maximal exercise were carried out (Robinson et al., 1966; Ekblom et al., 1972, 1975, 1976; Buick et al., 1980; Spriet et al., 1986).”
Effect of erythropoietin administration on mammal aerobic power
Ekblom, B., & Berglund, B. (1991) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.1991.tb00276.x · Cited by 179
Determinants of Oxygen Uptake: Implications for Exercise Testing
Poole, D. C., & Richardson, R. S. (1997) · Sports Medicine · doi:10.2165/00007256-199724050-00003 · Cited by 152
Metadata
- Authors
- Spriet, L. L., Gledhill, N., Froese, A. B., & Wilkes, D. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1986-11-01
- Volume
- 61
- Issue
- 5
- Pages
- 1942-1948
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2341573236
- Cited by
- 112
- References
- 2
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.