Continuous monitoring of blood volume changes in humans
The DOI matches its Crossref record.
Abstract
The mass density of antecubital venous blood was measured continuously for 80 min/session with 0.1 g/l precision at a flow rate of 1.5 ml/min in six male subjects. Each person participated in two different sessions with the same protocol. To induce transvascular fluid shifts, the subjects changed from sitting to standing and from standing to supine positions. There was transient blood density shifts immediately after postural changes, followed by an asymptotic approach to a new steady-state blood density level. Additional deviations from a simple time course were regularly observed. Blood density increased by 3.5 +/- 1.4 (SD) g/l when standing after sitting and decreased by 5.0 +/- 1.2 g/l while supine after standing. The corresponding half time of the blood density increase was 5.6 +/- 1.4 min (standing after sitting) and 6.9 +/- 3.1 min (supine after standing) of the blood density decrease. Erythrocyte density was calculated and did not change with body position. Whole-body blood density was calculated from plasma density, hematocrit, and erythrocyte density, assuming an F-cell ratio of 0.91. Volume shifts were computed from the density data; the subject's blood volume density decreased by 6.2 +/- 1.2% from sitting to standing and increased by 8.5 +/- 2.1% from standing to supine. Additional discrete plasma density and hematocrit measurements gave linear relations (P less than 0.001) between all possible combinations of blood density, plasma density, and hematocrit.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lower Body Negative Pressure: Physiological Effects, Applications, and Implementation
Goswami, N., Blaber, A. P., Hinghofer-Szalkay, H., & Convertino, V. A. (2019) · Physiological Reviews · doi:10.1152/physrev.00006.2018 · Cited by 217
Self-citationChristmas, K. M., & Bassingthwaighte, J. B. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01124.2016 · Cited by 42
Assessment of regional adipose tissue depots: a DXA and CT comparison in cadavers of elderly persons
Scafoglieri, A., Deklerck, R., Tresignie, J., De Mey, J., Clarys, J. P., & Bautmans, I. (2013) · Experimental Gerontology · doi:10.1016/j.exger.2013.07.005 · Cited by 25
“The density of the embalming solution was found to be 1.042 g/cm3, which approximates the density of blood in supine position (density 1.047 g/cm3) (Hinghofer-Szalkay and Greenleaf, 1987).”
InfluentialGravity, Microgravity and Artificial Gravity: Physiological Effects, Implementation and Applications
Goswami, N., Blaber, A. P., Valenti, G., Hinghofer-Szalkay, H., Evans, J., Bailey, D. M., Vernikos, J., Choukér, A., Green, D. A., White, O., et al. (2026) · Physiological Reviews · doi:10.1152/physrev.00055.2024 · Cited by 25
Self-citation
Metadata
- Authors
- Hinghofer-Szalkay, H., & Greenleaf, J. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-09-01
- Volume
- 63
- Issue
- 3
- Pages
- 1003-1007
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1784689761
- Cited by
- 125
- References
- 0
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous monitoring of blood volume changes in humans. https://app.cochat.ai/papers/10.1152/jappl.1987.63.3.1003
- The paper
- Hinghofer-Szalkay, H., & Greenleaf, J. E. (1987). Continuous monitoring of blood volume changes in humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1987.63.3.1003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.