Dynamics of hepatic lactate and glucose balances during prolonged exercise and recovery in the dog
The DOI matches its Crossref record.
Abstract
The present experiments were undertaken to assess dynamics of hepatic lactate and glucose balance in the over-night-fasted dog during 150 min of moderate-intensity treadmill exercise and 90 min of exercise recovery. Catheters were implanted chronically in an artery and portal and hepatic veins 16 days before experimentation. 3–3H-glucose was infused to determine hepatic glucose uptake, as well as tracer-determined glucose production by isotope dilution (Ra). At rest, net hepatic lactate output was 0.33 +/- 0.15 mg.kg-1.min-1 and increased to 2.26 +/- 0.82 mg.kg-1.min-1 after 10 min of exercise, after which it fell such that the liver was a net lactate consumer by the end of exercise and through recovery. In contrast to the rapid release of lactate, net hepatic glucose output rose gradually from 2.58 +/- 0.20 mg.kg-1.min-1 at rest to 8.87 +/- 0.85 mg.kg-1.min-1 after 60 min of exercise, beyond which it did not change significantly until the cessation of exercise. Hepatic glucose uptake at rest was 1.38 +/- 0.42 mg.kg-1.min-1 and did not change appreciably during exercise or recovery. Absolute hepatic glucose output (net glucose output plus uptake) rose from 3.96 +/- 0.45 mg.kg-1.min-1 at rest to 10.20 +/- 1.09 mg.kg-1.min-1 after 60 min of exercise and was 9.65 +/- 1.15 mg.kg-1.min-1 at 150 min of exercise. Ra rose from 3.34 +/- 0.21 mg.kg-1.min-1 to 7.58 +/- 0.73 and 8.59 +/- 0.77 mg.kg-1.min-1 at 60 and 150 min, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intra- and extra-cellular lactate shuttles
BROOKS, G. A. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200004000-00011 · Cited by 383
Mammalian fuel utilization during sustained exercise
Brooks, G. A. (1998) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/s0305-0491(98)00025-x · Cited by 253
Plasma Glucose Metabolism During Exercise in Humans
Coggan, A. R. (1991) · Sports Medicine · doi:10.2165/00007256-199111020-00003 · Cited by 122
Effect of adrenaline on glucose kinetics during exercise in adrenalectomised humans
Howlett, K., Galbo, H., Lorentsen, J., Bergeron, R., Zimmerman‐Belsing, T., Bülow, J., Feldt‐Rasmussen, U., & Kjær, M. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0911n.x · Cited by 68
Hepatic glucose production during exercise.
Kjær, M. (1998) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4899-1928-1_11 · Cited by 66
Importance of intrahepatic mechanisms to gluconeogenesis from alanine during exercise and recovery
Wasserman, D. H., Williams, P. E., Lacy, D. B., Green, D. R., & Cherrington, A. D. (1988) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1988.254.4.e518 · Cited by 65
Self-citation
Metadata
- Authors
- Wasserman, D. H., Lacy, D. B., Green, D. R., Williams, P. E., & Cherrington, A. D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-12-01
- Volume
- 63
- Issue
- 6
- Pages
- 2411-2417
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2181314579
- Cited by
- 51
- References
- 0
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.