CoChat

Graded cutaneous vascular responses to dynamic leg exercise

Taylor, W. F., Johnson, J. M., Kosiba, W. A., Kwan, C. M. · 1988 · Journal of Applied Physiology
Cited by 80

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The cutaneous vascular conductance-esophageal temperature (CVC-Tes) relationship was examined at five work loads (75–200 W) in each of four men to find whether there is a role for exercise intensity in the control of skin blood flow (SkBF). Several factors contributed to our evaluation of the CVC-Tes relationship during work. Laser-Doppler velocimetry (LDF) provided a continuous measure of SkBF that is not influenced by underlying muscle blood flow. Local warming to 39 degrees C at the site of measurement of SkBF provided a consistent skin temperature and facilitated observation of changes in LDF. Mean arterial pressure was measured noninvasively once per minute to calculate CVC. Supine exercise minimized baroreceptor-induced cutaneous vasoconstriction. Our major finding was that the internal temperature at which CVC began to rise during exercise (CVC threshold) was graded with work load beyond 125 W (P less than 0.05). In that range the CVC threshold increased by 0.16 degrees C for every increment of 25 W. The CVC threshold was never reached at the highest work load in three of the four subjects. There was no consistent effect of work load on the slope of the CVC-Tes relationship or on the internal temperature at which sweating began during exercise (sweat rate threshold). We conclude that the level of work beyond 125 W affects the CVC-Tes relationship in a graded fashion, principally through shifts in threshold.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1988.64.5.1803

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 80

Metadata

Authors
Taylor, W. F., Johnson, J. M., Kosiba, W. A., & Kwan, C. M.
Venue
Journal of Applied Physiology
Published
1988-05-01
Volume
64
Issue
5
Pages
1803-1809
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2302395436
Cited by
80
References
1
FWCI
1.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Graded cutaneous vascular responses to dynamic leg exercise. https://app.cochat.ai/papers/10.1152/jappl.1988.64.5.1803
The paper
Taylor, W. F., Johnson, J. M., Kosiba, W. A., & Kwan, C. M. (1988). Graded cutaneous vascular responses to dynamic leg exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.64.5.1803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.