Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 334

The DOI matches its Crossref record.

Pathological supply dependence of systemic and intestinal O2 uptake during endotoxemia

Nelson, D. P., Samsel, R. W., Wood, L. D., Schumacker, P. T.·1988·Journal of Applied Physiology

Abstract

When systemic delivery of oxygen (QO2 = blood flow X arterial O2 content) is reduced, the systemic O2 extraction ratio [(CaO2 - CVO2)/CaO2; where CaO2 is arterial O2 content and CVO2 is venous O2 content] increases until a critical limit is reached below which O2 uptake (VO2) becomes limited by delivery. Patients with adult respiratory distress syndrome and sepsis exhibit supply dependence of VO2 even at high levels of QO2, which suggests that a peripheral O2 extraction defect may be present. We tested the hypothesis that endotoxemia might produce a similar defect in the efficacy of tissue O2 extraction by determining the whole-body critical systemic QO2 (QO2 c) and critical extraction ratio in a control group of dogs and a group receiving a 5-mg/kg dose of Escherichia coli endotoxin. QO2 c was determined in each group by measuring VO2 as QO2 was gradually reduced by bleeding. The VO2 and QO2 of an isolated segment of small intestine were also measured to determine whether O2 extraction was impaired within a local region of tissue. The dogs were anesthetized, paralyzed, and ventilated with room air. Systemic QO2 was reduced in stages by hemorrhage as hematocrit was maintained. The systemic and intestinal critical points were determined from a plot of VO2 vs. QO2. The mean systemic QO2 c and critical O2 extraction ratio of the endotoxemic group (12.8 +/- 2.0 and 0.54 +/- 0.11 ml.min-1.kg-1) were significantly different from control (6.8 +/- 1.2 and 0.78 +/- 0.04) (P less than 0.001), indicating that endotoxin administration impaired systemic extraction of O2. Endotoxin also increased base-line systemic VO2 [6.1 +/- 0.7 (before) to 7.4 +/- 0.1 (after)] (P less than 0.001). The critical and maximal intestinal O2 extraction ratios of the endotoxemic group (0.47 +/- 0.10 and 0.71 +/- 0.04) were significantly less than control (0.69 +/- 0.06 and 0.83 +/- 0.05) (P less than 0.001). In addition, intestinal reactive hyperemia disappeared in six of seven endotoxemic dogs, whereas it remained intact in all control dogs. Thus endotoxin reduced the ability of tissues to extract O2 from a limited supply at the whole body level as well as within a 40- to 50-g segment of small intestine. These results could be explained by a defect in microvascular regulation of blood flow that interfered with the optimal distribution of a limited QO2 in accordance with tissue O2 needs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1988.64.6.2410

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 334

Metadata

Authors
Nelson, D. P., Samsel, R. W., Wood, L. D., & Schumacker, P. T.
Venue
Journal of Applied Physiology
Published
1988-06-01
Volume
64
Issue
6
Pages
2410-2419
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2178915660
Cited by
334
References
0
FWCI
12.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pathological supply dependence of systemic and intestinal O2 uptake during endotoxemia. https://app.cochat.ai/papers/10.1152/jappl.1988.64.6.2410
The paper
Nelson, D. P., Samsel, R. W., Wood, L. D., & Schumacker, P. T. (1988). Pathological supply dependence of systemic and intestinal O2 uptake during endotoxemia. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.64.6.2410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.